Skip to main content
Equipment catalogPowerTitan 2.0 ST5015UX-2H
Sungrow

PowerTitan 2.0 ST5015UX-2H

PowerTitan 2.0 — 2.5MW/5MWh liquid-cooled battery energy storage system container

StorageBattery energy storageModelled
PowerTitan 2.0 ST5015UX-2H by Sungrow
Nominal energy capacity
5.015MWh
AC apparent power
2.52MVA
Storage duration
2–4h
DC voltage
1500V

Characteristics

4 of 7 fields · all sourced · retrieved 2026-09-04
Nominal energy capacity
5.015MWh
AC apparent power
2.52MVA
Storage duration
2–4h
DC voltage
1500V

Sungrow's PowerTitan 2.0 integrates a 2520 kW string PCS and 5015 kWh of LFP batteries into a single 20 ft container that outputs AC power directly. The ST5015UX-2H is the two-hour variant, built on 3.2 V / 314 Ah cells in a 416S12P arrangement running between 1123.2 V and 1497.6 V DC, with a transformerless 690 V AC connection, an IP55 enclosure and a -30 to 50 °C operating range that derates above 45 °C. Sungrow presents the unit as pre-assembled and function-tested in the factory, with the electrical and battery cabinets kept separate to prevent thermal runaway, intelligent liquid cooling with automatic coolant refilling, and ArcDefender arc detection stated at a 100% detection rate and shutdown within 0.2 seconds. Cluster control lets each battery rack charge and discharge independently, which the manufacturer credits with an 8% gain in discharge capacity, while the single-sided door and back-to-back layout are claimed to cut footprint by 10-30% against traditional ESS.

Manufacturer datasheet (30)

Cell type
LFP 3.2 V / 314 Ah
Battery configuration
416S12P
Nominal voltage range
1123.2 V - 1497.6 V
AC current distortion rate
< 3 % ( Nominal Power )
DC component
< 0.5 %
Nominal AC voltage
690 V
AC voltage range
621 V - 759 V
Termination (LV)
352 A * 3 Phase * 6
Power factor
> 0.99 ( Nominal Power )
Adjustable range of reactive power
- 100 % - 100 %
Nominal frequency
50 Hz
Isolation method
Transformerless
Dimension (W * H * D)
6058 mm * 2896 mm * 2438 mm
Weight
42500 kg
Degree of protection
IP55
Anti-corrosion degree
C3
Operation ambient temperature range
﹣30 ℃ - 50 ℃ ( > 45 ℃ Derating )
Operation humidity range
0 % - 100 % ( Non-condensing )
Maximum operation altitude
4000 m
Temperature control method
Intelligent Liquid Cooling
Fire suppression system
FACP, FK5112, Flammable gas detector, Smoke detector, Heat detector, Sounder beacon, Alarm bell, Warning sign, Extinguishant abort button, Ventilation system, Pressure relief port, Manual automatic switching and emergency starting device(Default) Sprinkler, Vent panel, Aerosol ( Optional )
Communication
Ethernet
Standard
IEC61000, IEC62619, IEC62933,AS3000,UKCA,G99,UN38.3/UN3536,CE,IEC62477
Transport and assembly
Pre-assembled, no battery module handling on site, transportation of complete system
Electrical safety
Electrical safety management, overcurrent fast breaking and arc extinguishing protection
Cabinet separation
The electrical cabinet and battery cabinet are separated to prevent thermal runaway
Door and layout design
Front single-door-open design, supporting back to back layout drawing
Factory commissioning
Function test in factory, limited on-site work, accelerate commissioning process
Container format
5MWh batteries in just a 20ft container
Minimum spacing between containers
15 cm