Skip to main content
Nel Hydrogen

A485

Atmospheric Alkaline A-Series — Industrial-grade alkaline. Built to last.

HydrogenAlkaline electrolyserModelled
A485 by Nel Hydrogen
Nominal power
2.2MW
Specific energy
50kWh/kg
H2 output
485Nm3/h
H2 output pressure
0.03bar

Characteristics

7 of 9 fields · all sourced · retrieved 2026-09-02–2026-09-04
Nominal power
2.2MW
Specific energy
50kWh/kg
H2 output
485Nm3/h
H2 output pressure
0.03bar
H2 purity
99%
Water consumption
10l/kg
Minimum turndown
15%

Nel's A-Series is a range of atmospheric alkaline electrolysers built around MW-class stack modules for on-site hydrogen generation, with a modular design meant to ease installation and integration with the balance of plant. The A485 module produces up to 485 Nm³/h (1,046 kg/24 h) at 0.03 barg, drawing 4.5 kWh/Nm³ (50 kWh/kg) at the stack from a 25% KOH electrolyte, and turns down to 15% of capacity. Identical modules are multiplied to reach plant scale: the AWE 100 standard plant is rated 100 MW for a nominal 19,400 Nm³/h (41,840 kg/24 h), at 4.5 kWh/Nm³ at the stack and 4.7 kWh/Nm³ across the plant. Nel presents the platform as low-pressure and serviceable, with stacks designed for cell replacement rather than full disposal and a stated 20+ year operational life, for uses such as steel, green ammonia, generator cooling, sustainable aviation fuel and shipping.

Manufacturer datasheet (17)

Electrolyte
25% KOH solution
Maximum production rate (kg/24 h)
1,046 kg/24 h (+0/-3%)
Ramp rate (% of full-range)
> 10% per minute
DI water pressure
2 to 16 barg (29 to 232 psig)
Input water quality
Deionized Water, < 1 μS/cm
Electrical requirements, DC (Cell Stack)
355 to 414 VDC; 775 to 5,150 A
Electrical requirements, Electrolyte System
400 VAC, three phase plus neutral and protective earth, 50 Hz or 480 VAC, three phase and protective earth, 60 Hz
Dimensions W x D x H
14.1 m x 4.3 m x 4.3 m (46.3 ft x 14.1 ft x 14.1 ft)
Weight, operational
71,440 kg (157,498 lbs)
Standard siting location
Indoor, pad mounted or concrete pier mounted
Ambient temperature
5 to 40°C (41 to 104°F)
Altitude range
Sea Level to 1,000 m (3,281 ft)
Environmental considerations
DO NOT FREEZE
Operational life
20+ year operational life
Uptime
90%+ uptime proven in commercial operations
Factory acceptance testing
Factory acceptance testing before shipment
Support