Mechanical vapour recompression (MVR) of low-pressure steam - lift, kWh/t, COP and steam cost against boilers
Electric compression of low-pressure waste steam to a useful pressure: saturation lift (IAPWS-IF97), kWh per tonne and COP on the DOE method, installed CAPEX on the TNO/Klop scale law, and the steam cost in EUR/t against gas and electric boilers, with the CO2 avoided.
- CurrencyEUR 2015
- Battery limitinstalled
- 88 documented assumptions
- Updated2 Nov 2026
Mass and energy balance
What the asset draws and delivers for the case and load you choose.
Reference case
Equivalent hours per year at the rated steam output. TNO assumes 8,000 h (baseload). MVR follows a continuous waste-steam source; below 7,000 h the capital term rises fast and no part-load data was sourced, so the range stops there.
Flows
- In: Electricity—
- In: Low-pressure steam (suction)—
- In: Desuperheating water—
Asset
Mechanical vapour recompressor (steam MVR)
- Out: Recompressed saturated steam—
Annual quantities at the current usage. Band width: share of energy in; non-energy flows are not to scale.
Saturated steam delivered at the discharge pressure, after desuperheating (injection water included). TNO gives about 1 t/h as the practical minimum; Spilling steam compressors cover 1 to 20 t/h, up to 60 bar g. Costs are sourced between 2.6 and 43 MWth (about 4.5 to 75 t/h at 4 bar); outside, the CAPEX is an extrapolation and the page flags it.
- Compressor electric power
- — kW
- Latent heat delivered
- — MW
- Low-pressure steam taken
- — t/h
- Compression stages
- — stages
CAPEX
Specific cost at this size, what backs it, and how it behaves with scale.
Specific CAPEX at this size
—
Reference size 2.647 t/h
Derived from TNO
Model value: the reference case CAPEX scaled to the thermal output. Customized: your own installed figure (vendor or EPC quote), used as is at every size and no longer sourced.
Log in to view this sensitivity chart.
- Ex-factory
- Installed· this figure
- Fully financed
Included
- Equipment
- Installation, civil works and engineering
Not included
- Working capital
- Contingency
Added at project level
- Working capital layer, from the project settings
- Contingency, from the project settings
Project figures
Values passed to project mode when this asset is added to a project.
Mechanical vapour recompressor (steam MVR)Concept sketch, not to scale · drag to rotate
- Electricity in
- —
- Low-pressure steam (suction) in
- —
- Desuperheating water in
- —
- Recompressed saturated steam outMain product
- —
- CAPEX to the battery limit
- —
- Fixed O&M
- —
- Variable O&M, excluding feedstocks
- 0 EUR/year
- Asset lifetime
- 10 years
Log in to add this asset to a project.
Steam cost (MVR)
A standalone indicator for a quick read. Project mode recomputes it for the whole system.
—
- Steam cost - capital—
- Steam cost - fixed O&M—
- Steam cost - electricity—
Linked to the balance above
Equivalent hours per year at the rated steam output. TNO assumes 8,000 h (baseload). MVR follows a continuous waste-steam source; below 7,000 h the capital term rises fast and no part-load data was sourced, so the range stops there.
Absolute pressure of the low-pressure steam at the compressor inlet, taken as saturated. DOE recommends an inlet above atmospheric. Sub-atmospheric evaporator vapour (fans) is outside this range.
Discharge over suction pressure. DOE: below 2 per stage; TNO: about 3 in practice, guideline maximum 6. The page counts the stages at 2 per stage.
Overall isentropic, wire-to-steam efficiency. 75 % is the DOE table basis. Fans and centrifugal machines quote higher impeller efficiencies, but not on the same basis.
Delivered price excluding VAT and recoverable taxes. Default 121.7 EUR/MWh is Eurostat's EU27 band IF for 2025-S2; range from France band IG (61.4) to the EU band IC (183.7).
For the gas boiler benchmark only. Delivered price on a gross calorific value basis, excluding VAT. Default 48.3 EUR/MWh is Eurostat's EU27 band I4 for 2025-S2.
For the gas boiler benchmark only. Default 73.43 EUR/t is the 2025 average EU ETS allowance price (Instrat).
For the benchmark and the CO2 avoided. 87 % is the IEA (2025) figure; 93 % the DEA annual average for a gas heat-only boiler.
CO2 per MWh of electricity drawn by the compressor. 0.224 is the EU 2023 average (SDES after IEA); 0.363 Germany 2024 (UBA); 0 for a renewable supply contract.
Yearly O&M as a fraction of the investment. TNO (after Navigant 2019): 1 to 4 %; the default is the middle of that range.
Real rate for the capital annuity, as a fraction. Default 5 % is SINTEF's (2025). Costs are constant euros, so the rate is real. The annuity runs over the TNO service life of 10 years.
Log in to view this sensitivity chart.
Benchmarks
This model's figures against published references and reference cases.
COP, -
3.5 TNO MIDDEN factsheet
10 TNO MIDDEN factsheet
Electricity as share of boiler heat, %
5 DOE Steam Tip Sheet #11
10 DOE Steam Tip Sheet #11
Specific CAPEX (installed), EUR/kWth
260 TNO MIDDEN factsheet
600 TNO MIDDEN factsheet
Specific work (DOE units), Btu/lb
72.6 DOE Steam Tip Sheet #11
Reference cases at this size and usage
Log in to compare the reference cases.
All results
Every model output at the current settings, grouped, with the sensitivity charts.
76 outputs · 6 groups · 18 also shown above, dimmed
Steam cost
6- Electricity share of steam cost
- Computing%
- Cost per MWh of latent heat
- ComputingEUR/MWh
Against boilers
14- Gas boiler steam cost (fuel and CO2)
- ComputingEUR/t
- Gas boiler - gas
- ComputingEUR/t
- Gas boiler - CO2
- ComputingEUR/t
- Electric boiler steam cost (energy)
- ComputingEUR/t
- Saving against the gas boiler
- ComputingEUR/t
- Saving against the electric boiler
- ComputingEUR/t
- Yearly saving against the gas boiler
- ComputingEUR/year
- Breakeven electricity price against gas
- ComputingEUR/MWh
- Boiler duty per tonne
- ComputingMWh/t
- Gas price (NCV)
- ComputingEUR/MWh
- Gas CO2 factor
- Computingt/MWh
- Gas boiler fuel per tonne
- ComputingMWh/t
- Electric boiler electricity per tonne
- ComputingMWh/t
CO2
4- CO2 avoided per tonne
- Computingkg/t
- CO2 avoided per year
- Computingt/year
- Gas boiler CO2 per tonne
- Computingkg/t
- MVR indirect CO2 per tonne
- Computingkg/t
Compression
22- Specific power
- ComputingkWh/t
- Saturation temperature lift
- ComputingK
- Isentropic specific power
- ComputingkWh/t
- Efficiency penalty
- Computingratio
- Specific work per kg delivered
- ComputingkJ/kg
- Discharge pressure
- Computingbar
- Suction saturation temperature
- ComputingC
- Discharge saturation temperature
- ComputingC
- Pressure ratio per stage
- Computingratio
- Ratio above common practice
- Computingbool
- Property fit extrapolated
- Computingbool
- Isentropic work
- ComputingkJ/kg
- Compression work
- ComputingkJ/kg
- Superheat at discharge
- ComputingkJ/kg
- Injection water per kg of suction steam
- Computingkg/kg
- Steam delivered per kg of suction steam
- Computingkg/kg
- Suction steam enthalpy
- ComputingkJ/kg
- Delivered steam enthalpy
- ComputingkJ/kg
- Latent heat at discharge
- ComputingkJ/kg
Flows
12- Injection water flow
- Computingt/h
- Electricity per year
- ComputingMWh/year
- Latent heat per year
- ComputingMWh/year
- Full-load hours used
- Computingh/year
- Capacity factor
- Computing%
Capital and O&M
18- Total CAPEX
- ComputingMEUR
- Bare equipment (implied)
- ComputingEUR
- Installation (implied)
- ComputingEUR
- CAPEX per kW of compressor power
- ComputingEUR/kW
- Installed to bare equipment ratio
- Computingratio
- Installed CAPEX at 2.6 MWth
- ComputingEUR/kWth
- Installed CAPEX at 43 MWth
- ComputingEUR/kWth
- Scale exponent from the TNO anchors
- Computingratio
- TNO small anchor thermal size
- ComputingMW
- TNO large anchor thermal size
- ComputingMW
- Size outside cost anchors
- Computingbool
- Capital recovery factor
- Computing1/year
- Annualised CAPEX
- ComputingEUR/year
- Electricity cost per year
- ComputingEUR/year
- Total annual cost
- ComputingEUR/year
Sensitivities
6 chartsLog in to view this sensitivity chart.
Log in to view this sensitivity chart.
Log in to view this sensitivity chart.
Log in to view this sensitivity chart.
Log in to view this sensitivity chart.
Log in to view this sensitivity chart.
Sources
88 documented assumptions · 11 sources
- energy.govU.S. DOE AMO, Steam Tip Sheet #11, Use vapor recompression to recover low-pressure waste steam (2012)energy table at 75 % efficiency, limits, 5-10 % of boiler energy
- iapws.orgIAPWS R7-97(2012), Industrial Formulation 1997saturation temperature equation (Eq. 31), coefficients and check values
- webbook.nist.govNIST Chemistry WebBook, water (IAPWS-95) saturation tableenthalpies, cp and cv
- energy.nlTNO / PBL MIDDEN factsheet, Industrial mechanical vapour recompression (Marsidi 2018, after Klop 2015)CAPEX, O&M, lifetime, COP, pressure ratios
- arxiv.orgGalteland, Hadler-Jacobsen, Kauko (SINTEF), Techno-economic optimization of hybrid steam-electric energy systems, arXiv:2506.14252 (2025)discount rate
- ec.europa.euEurostat nrg_pc_205 and nrg_pc_203, non-household electricity and gas prices excl. VAT, 2025-S2
- ipcc-nggip.iges.or.jpIPCC 2006 Guidelines Vol. 2 Ch. 2natural gas 56,100 kg CO2/TJ (NCV)
- iea.orgIEA, Can low-temperature heat in factories be electrified competitively? (Dec 2025)gas boiler 87 %
- ens.dkDanish Energy Agency, Technology Data, data sheets 41 (electric boiler, 99 %) and 44 (gas boiler, 93 %)
- energy.instrat.plInstrat, EU ETS 2025 summaryaverage allowance price 73.43 EUR/t
- statistiques.developpement-durable.gouv.frSDES, Key figures on climate 2025EU grid 224 g CO2/kWh in 2023 (after IEA); UBA 2025: Germany 363 g CO2/kWh in 2024
About
Calculator context
About
Calculator context
A screening model of mechanical vapour recompression (MVR) of steam: an electric fan, centrifugal or piston compressor, one or more stages, takes low-pressure waste steam or evaporator vapour, raises it to a useful pressure, and a water spray brings it back to saturation. It is built for a feasibility study that has to stand in front of a lender, and it answers one question: what does a tonne of recompressed steam cost against raising it in a gas or an electric boiler. Saturation temperatures at suction and discharge come from the IAPWS-IF97 saturation equation (Eq. 31, reproduced on the IF97 check values). The compression work is the ideal-gas isentropic work from saturated suction divided by an overall wire-to-steam efficiency, followed by water injection to saturation, the basis of the U.S. DOE Steam Tip Sheet #11 table (75 % efficiency, 80 F water). This is an independent check, not a calibration: the model gives 19.1 to 74.1 Btu/lb at ratios 1.2 to 2.0 from 15 psig, against DOE's 18.6 to 72.6 (+2 to +3 %). Enthalpies come from linear fits of the NIST saturation table between 1 and 10 bar (under 0.5 % error); above 10 bar of discharge they are extrapolated, and the page flags it. The COP is the latent heat of the delivered steam divided by the electricity per tonne.
The installed CAPEX follows the TNO/PBL MIDDEN factsheet (Marsidi 2018, after Klop 2015, 2015 EUR): bare equipment 302 EUR/kWth at 2.65 MWth and 132 EUR/kWth at 43 MWth, installed at twice the bare cost (the printed 260-600 EUR/kWth range) or three times (the factsheet text, second reference case), scaled on the latent heat delivered with an exponent of 0.703 derived from those two anchors. A customized installed figure is used as is. O&M is 1-4 % of CAPEX a year (TNO), the annuity runs over TNO's 10-year service life at a real rate. The low-pressure steam and the injection water are taken at zero cost: the result is a service cost, and project mode prices the waste steam through its inlet if it has a value on your site.
At 10 t/h, 2 to 4 bar abs, 75 % efficiency, 8,000 h, 121.7 EUR/MWh (Eurostat EU band IF, 2025-S2), 5 % and 2.5 % O&M, the model lifts the saturation temperature by 23.4 K for 48.0 kWh per tonne, a COP of 12.3, and an installed CAPEX of 2.81 MEUR (476 EUR/kWth); the steam costs 11.3 EUR/t, about half of it electricity. The same steam costs 50.1 EUR/t in gas and CO2 alone in an 87 % gas boiler (48.3 EUR/MWh GCV, 73.43 EUR/t CO2) and 78.2 EUR/t in electricity in a 99 % electric boiler. Recompression uses 7.6 % of the boiler heat, inside DOE's 5-10 %, and avoids 137 kg of CO2 per tonne at the EU 2023 grid factor, about 11,000 t a year.
Read it with its limits. The CAPEX is in 2015 euros, not escalated, and excludes the grid connection; outside 2.6-43 MWth it is an extrapolation of the scale law, and the page flags it (1 t/h is about 0.6 MWth). The boilers are counted on energy and CO2 only, without their own capital, which favours them. The single-compression work formula slightly overstates multistage machines with interstage injection. Full-load hours below 7,000 h are left out: no part-load data was sourced.
Model
169 variables — inputs, calculations and outputs, with their dependencies.
Model
169 variables — inputs, calculations and outputs, with their dependencies.
| Variable | Value | Unit | Depends on |
|---|---|---|---|
| 10 | t/h | — | |
| 8000 | h/year | — | |
| 1 | — | — | |
| 0 | — | — | |
| 600 | EUR/kWth | — | |
| 2 | bar | — | |
| 2 | — | — | |
| 75 | % | — | |
| 121.7 | EUR/MWh | — | |
| 48.3 | EUR/MWh | — | |
| 73.43 | EUR/t | — | |
| 87 | % | — | |
| 0.224 | t/MWh | — | |
| 0.025 | ratio | — | |
| 0.05 | ratio | — |
| Variable | Formula | Unit | Depends on |
|---|---|---|---|
if((<=)+(<=)+(>)+(!=)*(!=)+(<)+(>)+(>=)*(<=)+(<)+(<=)+(*>=)+(<=)+(>)+(<)+(<)+(<)+(<=)+(>)+(<)+(<)+(<)+(>=)>,,) | bool | ||
(*)^ | — | ||
*+*+ | — | ||
**+*+ | — | ||
**+*+ | — | ||
*/(--sqrt(*-**)) | — | ||
(+-sqrt((+)*(+)-*(+*)))/ | K | ||
(*)^ | — | ||
*+*+ | — | ||
**+*+ | — | ||
**+*+ | — | ||
*/(--sqrt(*-**)) | — | ||
(+-sqrt((+)*(+)-*(+*)))/ | K | ||
* | kJ/kg |
| Variable | Formula | Unit | Depends on |
|---|---|---|---|
clamp(,,) | h/year | ||
/* | % | ||
* | bar | ||
- | K | ||
- | C | ||
- | C | ||
max(ceil(ln()/ln()-),) | stages | ||
^(/) | ratio | ||
if(>,,) | bool | ||
if(>,,) | bool | ||
+*(-) | kJ/kg | ||
+*(-) | kJ/kg | ||
+*(-) | kJ/kg | ||
/(-)***(^((-)/)-) | kJ/kg | ||
/max(,) | ratio | ||
* | kJ/kg | ||
+- | kJ/kg | ||
max(,)/max(-,) | kg/kg | ||
+ | kg/kg | ||
/*/ | kWh/t | ||
* | kWh/t | ||
*/ | kJ/kg | ||
/ | Btu/lb | ||
/max(,) | - | ||
/ | t/h | ||
- | t/h | ||
* | kW | ||
**/ | MW | ||
* | t/year | ||
* | t/year | ||
* | t/year | ||
*/ | MWh/year | ||
* | MWh/year | ||
*(-)/*/ | MWh/year | ||
* | MW | ||
* | MW | ||
+ln(/)/ln(/) | ratio | ||
if(==,,) | ratio | ||
* | EUR/kWth | ||
* | EUR/kWth | ||
if(>=,,clamp(*(/)^(-),,)) | EUR/kWth | ||
if((<)+(>)>,,) | bool | ||
** | EUR | ||
/ | MEUR | ||
/max(,) | EUR | ||
- | EUR | ||
/max(,) | EUR/kW | ||
if(<,/,(*(+)^)/max((+)^-,)) | 1/year | ||
* | EUR/year | ||
* | EUR/year | ||
* | EUR/year | ||
++ | EUR/year | ||
/max(,) | EUR/t | ||
/max(,) | EUR/t | ||
/max(,) | EUR/t | ||
++ | EUR/t | ||
/max(,)* | % | ||
/max(,) | EUR/MWh | ||
(-)*/ | MWh/t | ||
/max(*,)* | % | ||
/max(,) | EUR/MWh | ||
*/ | t/MWh | ||
/max(*,) | MWh/t | ||
* | EUR/t | ||
** | EUR/t | ||
+ | EUR/t | ||
/max(*,) | MWh/t | ||
* | EUR/t | ||
- | EUR/t | ||
- | EUR/t | ||
* | EUR/year | ||
(--)/max(/,) | EUR/MWh | ||
** | kg/t | ||
* | kg/t | ||
- | kg/t | ||
*/ | t/year |
Assumptions
88 assumptions used in the calculations
Assumptions
88 assumptions used in the calculations
Protects divisions against a zero denominator; small enough to leave every result unchanged.
Market range Not applicable (exact constant).
0.000001Numerical constantUsed in guards and flags, so no number is written inline.
Market range Not applicable (exact constant).
0Numerical constantUsed in the CRF, ratios and flags.
Market range Not applicable (exact constant).
1Numerical constantFactor 2 of the IF97 saturation-temperature backward equation (Eq. 31).
Market range Not applicable (exact constant).
2Numerical constantFactor 4 of the IF97 saturation-temperature backward equation (Eq. 31).
Market range Not applicable (exact constant).
4Numerical constantExponent 1/4 of the IF97 reduced pressure beta = (p / 1 MPa)^0.25 (Eq. 29b).
Market range Not applicable (exact constant).
0.25Numerical constantConverts fractions to percent.
Market range Not applicable (exact constant).
100%Unit conventionConverts percent inputs to fractions.
Market range Not applicable (exact constant).
0.01Unit conventionHours in a non-leap year; upper limit of the full-load hours.
Market range Not applicable (exact constant).
8760h/yearUnit conventionKilograms per tonne.
Market range Not applicable (exact constant).
1000kg/tUnit conventionKilojoules per kilowatt-hour.
Market range Not applicable (exact constant).
3600kJ/kWhUnit conventionKilojoules per megawatt-hour.
Market range Not applicable (exact constant).
3600000kJ/MWhUnit conventionKilowatt-hours per megawatt-hour.
Market range Not applicable (exact constant).
1000kWh/MWhUnit conventionKilowatts per megawatt.
Market range Not applicable (exact constant).
1000kW/MWUnit conventionEuros per million euros.
Market range Not applicable (exact constant).
1000000EUR/MEURUnit conventionTerajoules per megawatt-hour (3.6 GJ per MWh).
Market range Not applicable (exact constant).
0.0036TJ/MWhUnit conventionMegapascals per bar, to feed the IF97 equation written in MPa.
Market range Not applicable (exact constant).
0.1MPa/barUnit conventionKelvin to Celsius offset (ITS-90).
Market range Not applicable (exact constant).
273.15KUnit convention1 Btu/lb = 2.326 kJ/kg exactly (International Table Btu), to set the DOE table next to the model.
Market range Not applicable (exact constant).
2.326kJ/kg per Btu/lbUnit conventionCoefficient of the IF97 saturation-temperature backward equation, used to get Tsat at suction and discharge.
Market range Not applicable (exact coefficient of an international standard).
1,167.052145IAPWS-IF97 Region 4Coefficient of the IF97 saturation-temperature backward equation, used to get Tsat at suction and discharge.
Market range Not applicable (exact coefficient of an international standard).
-724,213.167032IAPWS-IF97 Region 4Coefficient of the IF97 saturation-temperature backward equation, used to get Tsat at suction and discharge.
Market range Not applicable (exact coefficient of an international standard).
-17.073847IAPWS-IF97 Region 4Coefficient of the IF97 saturation-temperature backward equation, used to get Tsat at suction and discharge.
Market range Not applicable (exact coefficient of an international standard).
12,020.824702IAPWS-IF97 Region 4Coefficient of the IF97 saturation-temperature backward equation, used to get Tsat at suction and discharge.
Market range Not applicable (exact coefficient of an international standard).
-3,232,555.032233IAPWS-IF97 Region 4Coefficient of the IF97 saturation-temperature backward equation, used to get Tsat at suction and discharge.
Market range Not applicable (exact coefficient of an international standard).
14.915109IAPWS-IF97 Region 4Coefficient of the IF97 saturation-temperature backward equation, used to get Tsat at suction and discharge.
Market range Not applicable (exact coefficient of an international standard).
-4,823.265736IAPWS-IF97 Region 4Coefficient of the IF97 saturation-temperature backward equation, used to get Tsat at suction and discharge.
Market range Not applicable (exact coefficient of an international standard).
405,113.405421IAPWS-IF97 Region 4Coefficient of the IF97 saturation-temperature backward equation, used to get Tsat at suction and discharge.
Market range Not applicable (exact coefficient of an international standard).
-0.238556IAPWS-IF97 Region 4Coefficient of the IF97 saturation-temperature backward equation, used to get Tsat at suction and discharge.
Market range Not applicable (exact coefficient of an international standard).
650.175348IAPWS-IF97 Region 4Above the critical pressure there is no saturated steam: the input is refused.
Market range Not applicable (physical limit).
220.64barIAPWS-IF97 Region 4Below the triple point there is no liquid-vapour equilibrium: the input is refused.
Market range Not applicable (physical limit).
0.006112barIAPWS-IF97 Region 4Gas constant of the ideal-gas isentropic work.
Market range Not applicable (physical constant).
0.461526kJ/(kg K)IAPWS-IF97Isentropic exponent of the ideal-gas work. Real steam near saturation is not an ideal gas; the DOE table check below shows the resulting error is +1 to +3 %.
Market range1.33Derived from NIST cp/cvShown with the isentropic exponent it supports.
Market range Not applicable (property value).
2.0789kJ/(kg K)NIST WebBookShown with the isentropic exponent it supports.
Market range Not applicable (property value).
1.5551kJ/(kg K)NIST WebBookOrigin of the linear h_fg(T) and h_g(T) fits.
Market range Not applicable (property value).
372.88KNIST WebBookIntercept of the latent-heat fit h_fg(T) = 2257.1 - 3.03 (T - 372.88).
Market range Not applicable (property value).
2,257.1kJ/kgNIST WebBookSlope of the latent heat with saturation temperature.
Market range Not applicable (fitted coefficient).
-3.03kJ/(kg K)Derived from NISTIntercept of the vapour-enthalpy fit h_g(T) = 2675.1 + 1.271 (T - 372.88).
Market range Not applicable (property value).
2,675.1kJ/kgNIST WebBookSlope of the saturated vapour enthalpy with saturation temperature.
Market range Not applicable (fitted coefficient).
1.271kJ/(kg K)Derived from NISTThreshold of the property-fit flag.
Market range Not applicable.
10.056barNIST WebBookBoilers in the benchmark raise steam from deaerated feedwater at 105 C.
Market range 20 C cold make-up (84 kJ/kg) would raise the boiler duty by about 15 %.
441kJ/kgNIST WebBookEnthalpy of the injection water, h_w = 4.18 x T [C].
Market range4.18kJ/(kg K)NIST WebBookTemperature of the desuperheating water injected after the compressor.
Market range Condensate at 60-100 C would raise the injected mass slightly; the effect on kWh/t is under 1 %.
26.7CDOE Steam Tip Sheet #11Sets the number of stages: ceil(ln r / ln 2).
Market range 2 per stage (DOE); fans 1.2-1.5, centrifugal compressors up to about 2-3 per stage.
2DOE Steam Tip Sheet #11Above it the page flags the case as beyond common practice.
Market range Guideline maximum 6 (TNO).
3TNO MIDDEN factsheetPhysical service life of the installation: annuity period of the CRF and lifetime exported to project mode (replacement schedule).
Market range No independent range cited.
10yearsTNO MIDDEN factsheetBare-equipment cost at the small anchor (2.647 MWth). Multiplied by the installation ratio of the reference case.
Market range302EUR/kWthTNO MIDDEN factsheetBare-equipment cost at the large anchor (43.12 MWth).
Market range132EUR/kWthTNO MIDDEN factsheetElectric input of the small cost anchor.
Market range Not applicable.
0.257MWTNO MIDDEN factsheetCOP of the small cost anchor, used to put it on a thermal basis.
Market range TNO: COP 3.5-10, sometimes higher.
10.3-TNO MIDDEN factsheetElectric input of the large cost anchor.
Market range Not applicable.
4.4MWTNO MIDDEN factsheetCOP of the large cost anchor.
Market range TNO: COP 3.5-10, sometimes higher.
9.8-TNO MIDDEN factsheetReference size of the CAPEX scale law, on thermal output.
Market range Not applicable.
2.647MWDerived from TNOInstalled-to-bare ratio of the default reference case (total = 2 x bare).
Market range x2 (printed range) to x3 (text reading), TNO.
2TNO MIDDEN factsheetInstalled-to-bare ratio of the conservative reference case.
Market range x2 (printed range) to x3 (text reading), TNO.
3TNO MIDDEN factsheetEconomy of scale on thermal output: compressor size follows the volume flow, which follows the steam flow, not the shaft power. Above 43 MWth and below 2.6 MWth the law is extrapolated.
Market range0.703Derived from TNOKeeps the scale law finite; set well outside the slider box.
Market range Not applicable (guard).
100EUR/kWthNumerical guardKeeps the scale law finite; set well outside the slider box.
Market range Not applicable (guard).
2500EUR/kWthNumerical guardCase 1: TNO total installed cost = 2 x bare equipment (printed 260-600 EUR/kWth range).
Market range Not applicable.
1Selector codeCase 2: TNO text reading, installation twice the equipment, total = 3 x bare.
Market range Not applicable.
2Selector codeConverts the Eurostat gas price (GCV) to an NCV price for an NCV boiler efficiency.
Market range0.9IPCC 2006Emission factor of the gas boiler benchmark.
Market range56100kg/TJIPCC 2006Efficiency of the electric boiler benchmark.
Market range99%DEA Technology DataLower published COP, set against the model COP.
Market range3.5-TNO MIDDEN factsheetUpper typical published COP, set against the model COP.
Market range10-TNO MIDDEN factsheetLower end of the DOE energy share.
Market range5%DOE Steam Tip Sheet #11Upper end of the DOE energy share.
Market range10%DOE Steam Tip Sheet #11Lower end of the TNO installed range.
Market range260EUR/kWthTNO MIDDEN factsheetUpper end of the TNO installed range.
Market range600EUR/kWthTNO MIDDEN factsheetPublished value set against the model's Btu/lb output at the DOE configuration (1 barg suction is close to 15 psig = 2.03 bar abs).
Market range72.6Btu/lbDOE Steam Tip Sheet #11Ideal-gas isentropic work from saturated suction, divided by the efficiency, then desuperheating by water injection back to saturation at the discharge pressure. The efficiency is overall wire-to-steam, as in the DOE example: there is no separate motor efficiency. Multistage machines with interstage injection need slightly less work; the single-compression formula is kept because it is the one the DOE table validates.
Market range Not applicable.
—MethodSaturation temperatures at suction and discharge come from the IF97 backward equation, valid from the triple point to the critical point.
Market range Not applicable.
—MethodCOP = latent heat of the delivered steam at the discharge pressure / electricity per kg delivered. It is a heat-pump COP, not a boiler efficiency.
Market range Not applicable.
—DefinitionThe suction steam and the injection water are taken at zero cost: the steam cost is a service cost. If the low-pressure steam has a value on your site, project mode prices it through the inlet flow.
Market range Not applicable.
—Cost boundaryThe CAPEX is installed, without grid connection: exported to project mode with battery_limit = installed, so the project adds only its working layer and contingency. It is in 2015 euros, not escalated to today: add escalation through the Customized CAPEX if your study is in current euros.
Market range Not applicable.
—CAPEX boundaryBoth boilers raise the same saturated steam at the discharge pressure from 105 C feedwater, and are counted on energy and CO2 only: their own capital and O&M are left out. The MVR steam cost carries its capital, so the comparison favours the boilers.
Market range Not applicable.
—Benchmark scopeOver the whole slider box the specific power stays between about 10 and 147 kWh/t, the COP between 3.5 and 60, the lift between 5 and 82 K and the CO2 avoided between about 90 and 155 kg/t. The steam cost stays between about 2.8 and 47.5 EUR/t: it exceeds 40 EUR/t only at a ratio of 6 with the highest electricity price (183.7 EUR/MWh), and reaches its 47.5 EUR/t maximum, outside the 45 EUR/t bound, for a 1 t/h machine in the 3 x bare CAPEX case at 70 % efficiency, 7,000 h, 4 % O&M and 8 %. The property fits are extrapolated above 10 bar of discharge (flag), and the CAPEX law outside 2.6-43 MWth (flag). Full-load hours below 7,000 h are left out: the capital term grows as 1/hours and no part-load operating data was sourced.
Market range Not applicable.
—Validity domainConstant prices over the life, real discount rate, nothing escalated. The CAPEX keeps the TNO money year (2015); energy prices are 2025.
Market range Not applicable.
—Real terms conventionDefault of the discount rate input (0.05).
Market range5%SINTEF 2025Default of the electricity price input.
Market range121.7EUR/MWhEurostatDefault of the gas price input.
Market range48.3EUR/MWhEurostatDefault of the CO2 price input.
Market range73.43EUR/tInstratDefault of the gas boiler efficiency input.
Market range87%IEA 2025Default of the grid emission factor input.
Market range0.224t/MWhSDES / UBADefault of the O&M input.
Market range0.025ratioTNO MIDDEN factsheetDefault of the full-load hours input.
Market range8000h/yearTNO MIDDEN factsheetCatalogue product inside the size slider.
Market range20t/hSpilling product page