Integrally geared CO2 compressor for CCS
Compression of captured CO2 from about 1 bar to 110-150 bar dense phase, 50 to 10,000 t/d: stage-by-stage power with intercooling, dense-phase pump, trains, and cost per tonne from McCollum & Ogden, cross-checked against an 8-stage integrally geared design.
- CurrencyEUR 2023
- Battery limitinstalled
- 68 documented assumptions
- Updated2 Nov 2026
Mass and energy balance
What the asset draws and delivers for the case and load you choose.
Reference case
Share of the year the compressor runs at nominal flow. 80 % is the McCollum & Ogden value; it is the lever project mode sets from the capture unit upstream.
Flows
- In: Captured CO2—
- In: Electricity for the compressor drive and pump—
Asset
Integrally geared CO2 compressor for CCS (to dense phase)
- Out: Dense-phase CO2—
Annual quantities at the current usage. Outline: full capacity, 8,760 h. Fill: 80.0 % capacity factor. Band width: share of energy in; non-energy flows are not to scale.
Captured CO2 entering the compressor, in tonnes per day: the capacity the catalogue binds on and the flow project mode chains from capture. Default 2,700 t/d (MHI Compressor, Padeswood). Petra Nova is about 5,000 t/d. Below 1,000 t/d the cost correlation is extrapolated.
- Shaft power
- — MW
- Number of trains
- — -
- Number of stages (integrally geared)
- — -
- CO2 mass flow
- — kg/s
CAPEX
Specific cost at this size, what backs it, and how it behaves with scale.
Specific CAPEX at this size
—
Reference size 1,000 t/d
McCollum 2006, p. 5
Model value: McCollum & Ogden 2006 compressor and pump correlations, escalated from 2005 dollars to 2023 euros. Customized: the specific cost of your own quote at the flow you set, used as is (a quote is not scaled again); it is then no longer sourced.
Log in to view this sensitivity chart.
- Ex-factory
- Installed· this figure
- Fully financed
Included
- Equipment
- Installation, civil works and engineering
Not included
- Working capital
- Contingency
Added at project level
- Working capital layer, from the project settings
- Contingency, from the project settings
Project figures
Values passed to project mode when this asset is added to a project.
Integrally geared CO2 compressor for CCS (to dense phase)Concept sketch, not to scale · drag to rotate
- Captured CO2 in
- —
- Electricity for the compressor drive and pump in
- —
- Dense-phase CO2 outMain product
- —
- CAPEX to the battery limit
- —
- Fixed O&M
- —
- Variable O&M, excluding feedstocks
- 0 EUR/year
- Asset lifetime
- 30 years
Log in to add this asset to a project.
Levelised cost of compression
A standalone indicator for a quick read. Project mode recomputes it for the whole system.
—
- Compression cost: capital—
- Compression cost: O&M—
- Compression cost: electricity—
Linked to the balance above
Share of the year the compressor runs at nominal flow. 80 % is the McCollum & Ogden value; it is the lever project mode sets from the capture unit upstream.
Pressure of the captured CO2 at the compressor inlet. 1 bar (0.1 MPa) is McCollum's value; amine strippers deliver about 1.5 bar.
Dense-phase pressure delivered to the pipeline or the injection well. 150 bar (15 MPa) is McCollum's value; Petra Nova delivers 130 bar. The pump takes over from 73.8 bar, the critical pressure.
Price paid for the drive electricity. Default: Eurostat, EU27 non-household band ID, excluding VAT, first half of 2025.
Log in to view this sensitivity chart.
Benchmarks
This model's figures against published references and reference cases.
Specific energy, kWh/t
140.3 Daud 2019, Table 1
Number of stages (integrally geared), -
8 Daud 2019, p. 4
Intercooling temperature, C
38 Daud 2019, p. 4
Reference cases at this size and usage
Log in to compare the reference cases.
All results
Every model output at the current settings, grouped, with the sensitivity charts.
43 outputs · 7 groups · 15 also shown above, dimmed
Compression cost
6- Electricity share of the cost
- Computing%
- Capital-charge load penalty
- Computingratio
Energy
9- Compressor specific energy
- ComputingkWh/t
- Pump specific energy
- ComputingkWh/t
- Compressor power
- ComputingkW
- Dense-phase pump power
- ComputingkW
- Pump share of power
- Computing%
- Daud et al. specific energy
- ComputingkWh/t
- Specific energy vs Daud et al.
- Computingratio
Stages and trains
8- Power per train
- ComputingMW
- Pressure ratio per property band
- Computing-
- Overall pressure ratio
- Computing-
- Stage 1 power
- ComputingkW
- Stage 5 power
- ComputingkW
- Last band share
- Computing%
Heat and cooling
4- Heat rejected in the intercoolers
- ComputingMW
- Margin above the critical temperature
- ComputingK
CAPEX
7- CAPEX scale exponent applied
- Computing-
- Compressor CAPEX
- ComputingEUR
- Pump CAPEX
- ComputingEUR
- CAPEX per kW of shaft power
- ComputingEUR/kW
- Cost escalation factor
- ComputingEUR/USD
Flows
4- Operating hours
- Computingh/yr
- Electricity a year
- ComputingMWh/yr
Yearly costs
5- Capital recovery factor
- Computing1/yr
- Annualised CAPEX
- ComputingEUR/yr
- Electricity cost a year
- ComputingEUR/yr
- Total yearly cost
- ComputingEUR/yr
Sensitivities
5 chartsLog in to view this sensitivity chart.
Log in to view this sensitivity chart.
Log in to view this sensitivity chart.
Log in to view this sensitivity chart.
Log in to view this sensitivity chart.
Sources
68 documented assumptions · 8 sources
- itspubs.ucdavis.eduMcCollum & Ogden (2006), UC Davis ITS UCD-ITS-RR-06-14, Part I CO2 compressionfive-band stage power, 40 MW trains, dense-phase pump, compressor and pump cost correlations, CRF 0.15, CF 0.80, O&M 4 % (pp. 2-8)
- discovery.ucl.ac.ukDaud et al. (2019), J. Phys.Conf. Ser. 1349 012010: 8-stage integrally geared CO2 compressor, ratio 1.78, 38 C intercooling, 79 MW at 156.4 kg/s
- webbook.nist.govNIST Chemistry WebBook, CO2 phase change dataTc 304.18 K, Pc 73.80 bar
- chemengonline.comChemical Engineering, CEPCI 2023 annual average 797.9
- acikders.ankara.edu.trAnkara University KYM363, reproduction of the CE plant cost index2005 = 468.2
- data-api.ecb.europa.euECB, USD/EUR annual average 20231.0813
- ec.europa.euEurostat nrg_pc_205, EU27 non-household electricity band ID excl. VAT, 2025-S10.1246 EUR/kWh
- US DOE/NETL QGESS, Estimating CO2 transport and storage costs (DOE/NETL-2010/1447)30-year levelisation period
About
Calculator context
About
Calculator context
Compressor that takes captured CO2 from about 1 bar (1 to 1.5 bar, the outlet of an amine stripper) to the 110-150 bar dense phase of a CCS pipeline or injection well. The calculator gives the levelised cost of compression in EUR per tonne of CO2, without the value of the CO2 itself, plus the shaft power, the energy per tonne, the number of trains and stages, and the heat the intercoolers reject.
Thermodynamics. The method is McCollum & Ogden (UC Davis, 2006), Part I. The gas is compressed up to 73.8 bar, the critical pressure of CO2, in five bands of equal pressure ratio, each with its own compressibility factor and ratio of specific heats, and cooled back to 40 C before every band. Above 73.8 bar a pump takes over in the dense phase (630 kg/m3, efficiency 0.75). The reference case sets the isentropic efficiency of the stages: 0.75 (McCollum) or 0.85, the upper end of the range studied by Daud et al. (2019) for an 8-stage integrally geared machine. The physical stage count of an integrally geared compressor is shown apart, at the 1.78 stage ratio of Daud et al. The power is not recomputed on it, since the tabulated properties belong to the five bands. Trains are limited to 40 MW (IEA GHG PH4/6). A 75 MW single machine (Everllence RG) would need fewer trains.
Check against an independent design. Daud et al. print 79 MW of compression for 156.4 kg/s from 1.5 to 151 bar, about 140 kWh/t. This model gives 80-105 kWh/t over its range, lower because a pump does the last stage and the band properties are averages. The page shows the ratio. Shaft energy only: motor and gearbox losses are not added.
CAPEX and cost. Compressor and pump costs are the McCollum correlations (adapted from Hendriks 2004 and IEA GHG), in 2005 dollars, escalated to 2023 euros with the CEPCI (797.9 / 468.2) and the ECB 2023 rate. The compressor cost per kg/s falls as the train flow to the power -0.60, so the specific CAPEX falls with size until a second train is added. The source plots its curve from 1,000 t/d: from 50 to 1,000 t/d the same law is extrapolated and the CAPEX there is indicative. The source does not say what its capital cost includes; it is read as installed equipment. The levelised cost uses the source's CRF of 0.15, an O&M of 4 % of CAPEX a year and the electricity price you set (Eurostat EU27 industrial band by default). With the source inputs at 1,000 t/d the model reproduces McCollum Fig. 4 to the cent: 8.52 capital, 2.27 O&M and 6.81 power, in US$2005 per tonne.
Out of scope: dehydration (the water knocked out and the dryer are not costed, no sourced figure found), aftercooling below 31 C before the pump (so the heat rejected is a lower bound), and the value of the CO2. Chains with amine capture upstream and CO2 liquefaction or a pipeline downstream on the t/d CO2 flow.
Model
129 variables — inputs, calculations and outputs, with their dependencies.
Model
129 variables — inputs, calculations and outputs, with their dependencies.
| Variable | Value | Unit | Depends on |
|---|---|---|---|
| 2700 | t/d | — | |
| 80 | % | — | |
| 1 | — | — | |
| 1 | bar | — | |
| 150 | bar | — | |
| 0.1246 | EUR/kWh | — | |
| 0 | — | — | |
| 14500 | EUR/(t/d) | — |
| Variable | Formula | Unit | Depends on |
|---|---|---|---|
if((<=)+(<=)+(>)+(<=)+(*>=)+(<=)+(<)+(>)+(<)+(>)+(<=)+(<)>,,) | bool | ||
* | MPa | ||
* | MPa | ||
/max(,) | - | ||
/ | - | ||
if(==,,) | ratio | ||
/ | t/h | ||
**/(*) | kW | ||
**(/(-))*(^((-)/)-) | kW | ||
**(/(-))*(^((-)/)-) | kW | ||
**(/(-))*(^((-)/)-) | kW | ||
+ | kW | ||
/ | kg/s | ||
**(*^+*^(-)*ln()) | USD | ||
*/+ | USD | ||
(+)* | EUR | ||
/ | EUR/(t/d) | ||
/(+)* | % | ||
** | t/yr |
| Variable | Formula | Unit | Depends on |
|---|---|---|---|
/max(,) | - | ||
^(/) | - | ||
*/(*) | kg/s | ||
**(/(-))*(^((-)/)-) | kW | ||
**(/(-))*(^((-)/)-) | kW | ||
++++ | kW | ||
max(,ceil(/)) | - | ||
// | MW | ||
ceil(ln()/ln()) | - | ||
***(-)/(***) | kW | ||
/ | MW | ||
*/ | kWh/t | ||
*/ | kWh/t | ||
*/ | kWh/t | ||
/max(,)* | % | ||
/max(,)* | % | ||
/ | MW | ||
- | C | ||
- | K | ||
** | h/yr | ||
*** | t/yr | ||
*/ | MWh/yr | ||
*/ | MWh/yr | ||
// | EUR/USD | ||
if(>=,,clamp(,,)) | EUR/(t/d) | ||
if(>=,,) | - | ||
* | EUR | ||
** | EUR | ||
- | EUR | ||
/max(,) | EUR/kW | ||
| 1/yr | ||
* | EUR/yr | ||
* | EUR/yr | ||
** | EUR/yr | ||
++ | EUR/yr | ||
/(*) | ratio | ||
/* | EUR/t | ||
/ | EUR/t | ||
/ | EUR/t | ||
++ | EUR/t | ||
/max(,)* | % | ||
*/(*/) | kWh/t | ||
/ | ratio |
Assumptions
68 assumptions used in the calculations
Assumptions
68 assumptions used in the calculations
Lower limit in the input guards.
Market range Exact by definition.
0Numerical constantUnit multiplier in the guards, the train count and the Customized switch.
Market range Exact by definition.
1Numerical constantProtects divisions against a zero denominator.
Market range Exact by definition.
0Numerical constantConverts a percent into a fraction.
Market range Exact by definition.
0.01Numerical constantConverts a fraction into a percent; upper limit of a percent input.
Market range Exact by definition.
100Numerical constantConverts bar into MPa (1 bar = 0.1 MPa), the pressure unit of the McCollum equations.
Market range Exact by definition.
0.1Numerical constantBar per MPa in the McCollum pump power equation (the '10' of the source).
Market range Exact by definition.
10Numerical constantKilograms per tonne (the '1000' of the McCollum power equations).
Market range Exact by definition.
1000Numerical constantHours per day (the '24' of the McCollum power equations).
Market range Exact by definition.
24Numerical constantSeconds per hour (the '3600' of the McCollum compressor power equation).
Market range Exact by definition.
3600Numerical constantHours in a year.
Market range Exact by definition.
8760Numerical constantDays in a year (McCollum: m_year = m x 365 x CF).
Market range Exact by definition.
365Numerical constantkW per MW.
Market range Exact by definition.
1000Numerical constantkWh per MWh.
Market range Exact by definition.
1000Numerical constantConverts kelvin into degrees Celsius.
Market range Exact by definition.
273.15Numerical constantThe '36' of the McCollum pump power equation: m3 x bar per hour per kW (1 kW = 36 m3.bar/h).
Market range Exact by definition.
36McCollum 2006, p. 4Reference case 1: McCollum & Ogden 2006 compressor, isentropic stage efficiency 0.75.
Market range Not applicable.
1Selector codeReference case 2: high-efficiency integrally geared stages, isentropic efficiency 0.85, the upper end of the range studied by Daud et al. 2019.
Market range Not applicable.
2Selector codePressure at which the compressor hands over to the dense-phase pump: the critical pressure of CO2 (McCollum: compressor 0.1-7.38 MPa, pump 7.38-15 MPa).
Market range Fixed by CO2 properties.
7.38MPaMcCollum 2006, p. 2Critical pressure of CO2. A discharge pressure at or below it is not dense phase, so the input guard refuses it.
Market range Physical constant.
73.8barNIST WebBookCritical temperature of CO2 (about 31 C). The intercooler outlet at 40 C sits above it: the CO2 leaving the last stage is supercritical and must be cooled further to reach the 630 kg/m3 pump density.
Market range Physical constant.
304.18KNIST WebBookNumber of compression stages over which McCollum splits the CO2 properties (5 bands of Z and k, Mohitpour optimal ratio). It sets the thermodynamics; the physical stage count of an integrally geared machine is shown apart.
Market range No independent range cited.
5-McCollum 2006, p. 2Gas temperature at the inlet of every stage, after intercooling (40 C).
Market range313.15KMcCollum 2006, p. 2Isentropic efficiency of each compressor stage, reference case 1.
Market range0.75ratioMcCollum 2006, p. 2Isentropic efficiency of each stage, reference case 2 (high-efficiency integrally geared stages).
Market range0.85ratioDaud 2019, pp. 4-5Universal gas constant.
Market range Physical constant.
8.314kJ/(kmol.K)McCollum 2006, p. 2Molar mass of CO2.
Market range Physical constant.
44.01kg/kmolMcCollum 2006, p. 2Average compressibility factor of CO2 in stage 1 (McCollum band 0.1-0.24 MPa, 356 K average).
Market range No independent range cited.
0.995-McCollum 2006, p. 2Average ratio of specific heats Cp/Cv of CO2 in stage 1 (McCollum band 0.1-0.24 MPa).
Market range No independent range cited.
1.277-McCollum 2006, p. 2Average compressibility factor of CO2 in stage 2 (McCollum band 0.24-0.56 MPa, 356 K average).
Market range No independent range cited.
0.985-McCollum 2006, p. 3Average ratio of specific heats Cp/Cv of CO2 in stage 2 (McCollum band 0.24-0.56 MPa).
Market range No independent range cited.
1.286-McCollum 2006, p. 3Average compressibility factor of CO2 in stage 3 (McCollum band 0.56-1.32 MPa, 356 K average).
Market range No independent range cited.
0.97-McCollum 2006, p. 3Average ratio of specific heats Cp/Cv of CO2 in stage 3 (McCollum band 0.56-1.32 MPa).
Market range No independent range cited.
1.309-McCollum 2006, p. 3Average compressibility factor of CO2 in stage 4 (McCollum band 1.32-3.12 MPa, 356 K average).
Market range No independent range cited.
0.935-McCollum 2006, p. 3Average ratio of specific heats Cp/Cv of CO2 in stage 4 (McCollum band 1.32-3.12 MPa).
Market range No independent range cited.
1.379-McCollum 2006, p. 3Average compressibility factor of CO2 in stage 5 (McCollum band 3.12-7.38 MPa, 356 K average).
Market range No independent range cited.
0.845-McCollum 2006, p. 3Average ratio of specific heats Cp/Cv of CO2 in stage 5 (McCollum band 3.12-7.38 MPa).
Market range No independent range cited.
1.704-McCollum 2006, p. 3Largest compressor train: above it, the flow is split into parallel trains.
Market range 40 MW (IEA GHG PH4/6) to 75 MW (Everllence RG, vendor claim).
40000kWMcCollum 2006, p. 3Density of CO2 in the dense-phase pump.
Market range No independent range cited.
630kg/m3McCollum 2006, p. 4Efficiency of the dense-phase pump.
Market range No independent range cited.
0.75ratioMcCollum 2006, p. 4Pressure ratio per stage of an 8-stage integrally geared CO2 compressor, used to count the physical stages up to the cut-off pressure.
Market range No independent range cited.
1.78-Daud 2019, p. 4Intercooling temperature of the Daud et al. integrally geared design, a benchmark for the 40 C of McCollum.
Market range No independent range cited.
38CDaud 2019, p. 4Compression power printed by Daud et al. for their 8-stage integrally geared case, used for the independent specific-energy check.
Market range No independent range cited.
79MWDaud 2019, Table 1CO2 flow of the Daud et al. case.
Market range No independent range cited.
156.4kg/sDaud 2019, p. 4First coefficient of the compressor capital cost correlation (per kg/s of train flow).
Market range No independent range cited.
130000USD2005/(kg/s)McCollum 2006, p. 5Exponent of the first term of the compressor cost correlation, on train flow in kg/s.
Market range No independent range cited.
-0.71-McCollum 2006, p. 5Second coefficient of the compressor capital cost correlation, multiplied by ln(Pcut-off/Pinitial). It carries about 98 % of the compressor cost.
Market range No independent range cited.
1400000USD2005/(kg/s)McCollum 2006, p. 5Capacity exponent of the compressor cost: the McCollum term mtrain x mtrain^-0.60 grows as mtrain^0.40, so the cost per t/d falls as flow^-0.60 within one train. The second term (mtrain^0.29) and the pump cost (almost linear) weigh about 3 % at the nominal size.
Market range No independent range cited.
0.4-McCollum 2006, p. 5Variable part of the dense-phase pump capital cost.
Market range No independent range cited.
1110000USD2005/MWMcCollum 2006, p. 5Fixed part of the dense-phase pump capital cost.
Market range No independent range cited.
70000USD2005McCollum 2006, p. 5Chemical Engineering Plant Cost Index, 2005 annual average: base year of the McCollum costs.
Market range No independent range cited.
468.2-CEPCI 2005Chemical Engineering Plant Cost Index, 2023 annual average: target year of the costs.
Market range No independent range cited.
797.9-CEPCI 2023Converts 2023 dollars into 2023 euros.
Market range Exact annual average.
1.0813USD/EURECB 2023Capital recovery factor applied to the total capital cost.
Market range No independent range cited.
0.151/yrMcCollum 2006, p. 6Reference capacity factor of the source; the capital charge per tonne is shown as a penalty relative to it.
Market range No independent range cited.
0.8ratioMcCollum 2006, p. 6Yearly O&M as a share of the total capital cost.
Market range No independent range cited.
0.041/yrMcCollum 2006, p. 6Lower guard of the specific CAPEX clamp. The model gives about 9,000-160,000 EUR per t/d over the slider, so the guard never binds there.
Market range Not applicable.
1000EUR/(t/d)Model guardUpper guard of the specific CAPEX clamp; never binds inside the slider range (checked at the corners).
Market range Not applicable.
500000EUR/(t/d)Model guardMethod: five-band polytropic stage work from the CO2 inlet pressure to the critical pressure (7.38 MPa) with intercooling to 40 C between stages, trains of at most 40 MW, a dense-phase pump from 7.38 MPa to the discharge pressure, then the levelised cost of compression = (CRF + O&M factor) x CAPEX / tonnes a year + electricity x price. Reproduces McCollum Fig. 4 at 1,000 t/d (8.52 capital, 2.27 O&M, 6.81 power, US$2005/t) with the source inputs.
Market range Not applicable.
—Model scopeOut of scope: dehydration. The water knocked out in the intercoolers and the glycol or molecular-sieve dryer needed for pipeline specification are neither costed nor counted in the flows (no sourced figure found). The CO2 mass in equals the mass out.
Market range Not applicable.
—Model limitsThe pump density of 630 kg/m3 implies the CO2 is cooled below its critical temperature (31 C) after the last stage; that aftercooling duty is not added to the heat rejected, which is a lower bound (Daud et al. 2019 note the heat removed exceeds the isentropic work at high pressure).
Market range Not applicable.
—Model limitsThe compressor cost correlation is plotted by the source from 1,000 to 25,000 t/d. Between 50 and 1,000 t/d the calculator extrapolates the same power law: the CAPEX there is indicative.
Market range Not applicable.
—Model limitsBattery limit: the source gives the compressor and pump capital cost (adapted from Hendriks 2004 and IEA GHG PH4/6) without listing what it includes. It is read as installed equipment, so project mode adds working capital layers and contingency only.
Market range Not applicable.
—CAPEX boundaryService life exported to project mode as the replacement interval of the compressor train.
Market range No independent range cited.
30yearsNETL QGESS 2010Default of the electricity price input.
Market range0.1246EUR/kWhEurostat 2025-S1Independent benchmark of the compression energy per tonne: Daud et al. compression power divided by their CO2 flow (79,000 kW / (156.4 kg/s x 3.6 t/h per kg/s)).
Market range No independent range cited.
140.3kWh/tDaud 2019, Table 1Number of stages of the Daud et al. integrally geared design, benchmark for the physical stage count.
Market range No independent range cited.
8-Daud 2019, p. 4Reference size of the CAPEX scale law: the smallest flow at which the source plots its cost. The calculator also outputs the reproduction of the source at this flow when inputs are set to 1,000 t/d, 1 to 150 bar and 0.065 USD/kWh.
Market range Not applicable.
1000t/dMcCollum 2006, p. 8