Liquid CO2 storage vessels for a CO2 battery (ambient, ~70 bar): count, wall thickness, steel and cost per kWh
Carbon-steel bullets holding an Energy Dome-type CO2 battery's liquid CO2 at ambient temperature, 4 to 1,000 MWh. NIST densities, ASME UG-27 walls and the Seider vessel cost give vessel count, steel and installed EUR/kWh.
Open Jack
Founder · OpenJack
- CurrencyEUR 2023
- Battery limitinstalled
- 67 documented assumptions
- Updated2 Nov 2026
Mass and energy balance
What the asset draws and delivers for the case and load you choose.
Reference case
Full discharges a year you expect to sell. 365 is one cycle a day, the usual basis for daily-cycling long-duration storage. Fewer cycles spread the same vessel cost over fewer MWh.
Flows
- In: Liquid CO2 from the charge compression train—
Asset
Liquid CO2 storage vessels for a CO2 battery (ambient temperature, ~70 bar)
- Out: Liquid CO2 to the discharge expansion train—
Annual quantities at the current usage. Band width: share of energy in; non-energy flows are not to scale.
Electricity returned per full discharge of the CO2 battery. Sets the CO2 inventory the vessels must hold. 200 MWh is the Energy Dome standard plant (20 MW for 10 h, Sardinia and Latrobe Valley); the shared CO2 battery range runs from the 4 MWh Ottana demonstrator to 1,000 MWh.
- CO2 inventory
- — t
- Liquid CO2 volume
- — m3
- Number of vessels
- — vessels
- Steel mass of the vessel bank
- — t
CAPEX
Specific cost at this size, what backs it, and how it behaves with scale.
Specific CAPEX at this size
—
Reference size 200 MWh
Seider 4th ed. / IEEE Spectrum 2025
Model value: steel mass, Seider vessel price and installation factor. Customized: your own installed quote per kWh, used as is at every size; it is then no longer sourced.
Log in to view this sensitivity chart.
- Ex-factory
- Installed· this figure
- Fully financed
Included
- Equipment
- Installation, civil works and engineering
Not included
- Working capital
- Contingency
Added at project level
- Working capital layer, from the project settings
- Contingency, from the project settings
Project figures
Values passed to project mode when this asset is added to a project.
Liquid CO2 storage vessels for a CO2 battery (ambient temperature, ~70 bar)Concept sketch, not to scale · drag to rotate
- Liquid CO2 from the charge compression train in
- —
- Liquid CO2 to the discharge expansion train outMain product
- —
- CAPEX to the battery limit
- —
- Fixed O&M
- 0 EUR/year
- Variable O&M, excluding feedstocks
- 0 EUR/year
- Asset lifetime
- 30 years
Log in to add this asset to a project.
Vessel bank cost per MWh discharged
A standalone indicator for a quick read. Project mode recomputes it for the whole system.
—
- Vessel purchase part—
- Installation part—
Linked to the balance above
Full discharges a year you expect to sell. 365 is one cycle a day, the usual basis for daily-cycling long-duration storage. Fewer cycles spread the same vessel cost over fewer MWh.
Hours of discharge at rated power. Sets the rated power and the CO2 flow leaving the vessels, not their size. A cycle also needs a charge: on the Energy Dome standard frame it takes about as long as the discharge, so cycles x (charge + discharge) must fit in a year.
Tonnes of CO2 cycled per MWh discharged. 10 t/MWh is printed for the 200 MWh Sardinia plant (2,000 t, IEEE Spectrum 2025). The Energy Dome 2022 deck implies about 11.5 t/MWh (66.7 kWh/m3 at 1.3 L/kg). The whole inventory is sized as liquid at full charge.
Absolute pressure in the vessels. Energy Dome's 2022 deck gives 70 bar at ambient temperature; IEEE Spectrum reports compression to about 55 bar. It must stay above the CO2 saturation pressure at the hottest ambient temperature, or the liquid cannot be held.
Hottest temperature the uninsulated vessels reach. It sets the liquid density (NIST: 860 kg/m3 at 10 °C, 710 at 25 °C, 592 at 30 °C) and the saturation pressure. CO2 has no liquid above 31 °C; at 70 bar storage the limit is about 28.6 °C.
Inside diameter of each horizontal bullet, 12 m between tangents with 2:1 ellipsoidal heads. 3 m reflects the 'school bus' sized vessels reported at Sardinia. A larger diameter means fewer vessels but thicker walls.
Real rate used to annualise the vessel CAPEX. Costs are in constant 2023 euros, so the rate must be real (after inflation).
Service life of the vessel bank. Energy Dome states a 30+ year plant life with no degradation; static carbon-steel pressure vessels have no wear part to replace.
Log in to view this sensitivity chart.
Benchmarks
This model's figures against published references and reference cases.
CO2 inventory per MWh, t/MWh
10 IEEE Spectrum 2025
11.53 Energy Dome NETL 2022 (derived)
Liquid specific volume, L/kg
1.3 Energy Dome NETL 2022
Liquid volume per MWh, m3/MWh
14.99 Energy Dome NETL 2022 (derived)
Reference cases at this size and usage
Log in to compare the reference cases.
All results
Every model output at the current settings, grouped, with the sensitivity charts.
55 outputs · 6 groups · 13 also shown above, dimmed
Storage cost
5- Annualised vessel CAPEX
- ComputingEUR/year
- Capital recovery factor
- Computing1/year
CAPEX
14- Installed vessel CAPEX per kWh, scale law
- ComputingEUR/kWh
- Installed vessel CAPEX per kWh (model)
- ComputingEUR/kWh
- Purchased vessel cost per kWh
- ComputingEUR/kWh
- CAPEX per kWh as built
- ComputingEUR/kWh
- Whole-vessel rounding
- Computingratio
- Purchased vessels
- ComputingEUR
- Installation
- ComputingEUR
- CAPEX per tonne of CO2 stored
- ComputingEUR/t
- Purchased cost of one vessel, 2013
- ComputingUSD
- Purchased cost of one vessel, 2023 euros
- ComputingEUR
- Purchased cost per kg of steel
- ComputingEUR/kg
- Share of Energy Dome's whole-plant price
- Computing%
CO2 inventory and liquid
9- Liquid CO2 density at the hottest day
- Computingkg/m3
- CO2 saturation pressure at the hottest day
- Computingbar
- Pressure margin above saturation
- Computingbar
- Margin to the critical temperature
- Computing°C
Vessels and steel
15- Vessels needed (continuous)
- Computingvessels
- Volume of one vessel
- Computingm3
- Required vessel volume
- Computingm3
- Vessel volume per MWh
- Computingm3/MWh
- Vessel volume per tonne of CO2
- Computingm3/t
- Vapour-space penalty
- Computing%
- Gauge pressure
- Computingbar
- Design pressure (gauge)
- Computingbar
- Allowable stress
- ComputingMPa
- Shell wall thickness
- Computingmm
- Steel mass of one vessel
- Computingt
- Vessel weight for the cost law
- Computinglb
- Steel per MWh
- Computingt/MWh
Code and correlation checks
4- Thickness to radius ratio
- Computingratio
- Pressure to stress ratio
- Computingratio
- Thin-wall formula out of range
- Computingflag
- Cost law out of range
- Computingflag
Duty and chaining
8- Rated discharge power
- ComputingMW
- Discharge load hours
- Computingh/year
- Charge to discharge time ratio
- Computingratio
- Charge load hours
- Computingh/year
- Discharge capacity factor
- Computing%
- Energy discharged a year
- ComputingMWh/year
- CO2 flow leaving the vessels in discharge
- Computingt/h
Sensitivities
5 chartsLog in to view this sensitivity chart.
Log in to view this sensitivity chart.
Log in to view this sensitivity chart.
Log in to view this sensitivity chart.
Log in to view this sensitivity chart.
Sources
67 documented assumptions · 11 sources
- netl.doe.govEnergy Dome (J. Ferrari), CO2 Battery update, NETL TMCES Storage Workshop 2022liquid CO2 at 70 bar and ambient temperature, 1.3 L/kg, 66.7 kWh/m3, critical temperature 31 °C (slides 3-4)
- spectrum.ieee.orgIEEE Spectrum, E. Waltz, 21 Dec 2025Sardinia 20 MW / 200 MWh holds 2,000 t of CO2 in a few dozen pressure vessels; compression to about 55 bar
- webbook.nist.govNIST Chemistry WebBook SRD 69CO2 saturation table, liquid density and saturation pressure 10-30 °C
- checalc.comCheCalc pressure vessel guideASME VIII Div. 1 UG-27 shell formula, thin-wall limits, joint efficiency, corrosion allowance
- biosteam.readthedocs.ioBioSTEAM flash_vessel_design (after Seider et al.)design pressure rule, S = 15 ksi, wall thickness and Seider horizontal-vessel cost
- idaes-pse.readthedocs.ioIDAES SSLW costing docs (Seider et al.)vessel weight formula, carbon-steel density
- openpytea.readthedocs.ioOpenPyTEASeider 2016 horizontal vessel correlation (CE 567, 1,000-920,000 lb) and Towler & Sinnott fluids installation factors
- law.cornell.edu49 CFR 173.304bliquefied gas fill limited to 95 % of the liquid-phase density
- chemengonline.comChemical EngineeringCEPCI 2023 annual average 797.9
- data-api.ecb.europa.euECB reference rate USD/EUR, 2023 annual average 1.0813
- energy-storage.newsEnergy-Storage.news, 12 Apr 2023Energy Dome whole-plant price about EUR 220/kWh (vendor claim, comparison only)
About
Calculator context
About
Calculator context
An Energy Dome CO2 battery keeps its charged state as liquid CO2 at ambient temperature, in carbon-steel pressure vessels at about 70 bar (Energy Dome, NETL 2022). This calculator sizes and prices that vessel bank. It takes the energy capacity (MWh, the key shared by the six CO2 battery calculators), the CO2 inventory per MWh, the storage pressure, the hottest ambient day and the vessel diameter. It returns the liquid volume, the number of vessels, their wall thickness and steel mass, the installed CAPEX per kWh, and the vessels' share of the plant LCOS.
Inventory. 10 t of CO2 per MWh discharged is the default: IEEE Spectrum (Dec 2025) prints 2,000 t for the 200 MWh Sardinia plant. Energy Dome's 2022 deck implies about 11.5 t/MWh (66.7 kWh/m3 at 1.3 L/kg). That is a derived cross-check, within 15 %. The slider runs from 9 to 12 t/MWh. The whole inventory is sized as liquid at full charge.
Liquid. The density is the NIST saturated-liquid value at the hottest ambient temperature, interpolated between NIST points at 10, 25 and 30 °C. The interpolation is a little low between the points, which is conservative. Liquid can only be held while the CO2 saturation pressure at that temperature stays below the storage pressure. The calculator refuses a design that breaks this rule, and any hottest day at or above the 31 °C critical point. At 70 bar the limit is about 28.6 °C. The vessels are filled to 95 % at most: the 49 CFR rule for pressure receptacles, transposed to stationary storage.
Vessels. Each vessel is a horizontal bullet, 12 m between tangents, with 2:1 ellipsoidal heads; about 3 m in diameter matches the 'few dozen' school-bus-sized vessels reported at Sardinia. The shell thickness follows ASME VIII Div. 1 UG-27. The design pressure is 10 % above gauge (Seider rule), the allowable stress is 15 ksi carbon steel by default or 20 ksi for SA-516 Gr 70, welds are fully radiographed, and 3.175 mm is added for corrosion. Steel mass uses the Seider weight formula. Per-MWh results use the continuous vessel count, so they do not jump with rounding. The vessel count, total steel and total CAPEX use whole vessels.
Cost. Each vessel is priced from its weight with the Seider et al. (4th ed.) horizontal-vessel correlation. That gives an f.o.b. price including nozzles, manholes and supports, escalated with CEPCI 2023 / 567 and converted at the ECB 2023 rate. It is then multiplied by the Towler & Sinnott fluids-processing installation factor of 3.2, which gives installed ISBL direct cost in constant 2023 euros. The vessel bank is a numbering-up of identical vessels, so no economy of scale is applied: the cost per kWh does not fall with plant size. The cost per MWh discharged annualises that CAPEX with a real capital recovery factor over the vessel service life (30 years by default, Energy Dome) and the cycles a year. It is the vessels' share of the plant LCOS only.
What to defend, and what not. The vessel-only CAPEX comes out high. On default settings it is a large share of the roughly EUR 220/kWh Energy Dome quotes for the whole 20 MW / 200 MWh plant (vendor claim, 2023 euros, the same year as this calculator). That share is shown as an output. Each modelling choice pushes the cost up: 15 ksi rather than 20 ksi steel, a generic fluids installation factor whose 0.8 piping term is large for simple storage bullets, and 70 bar where IEEE reports about 55 bar. At 55 bar the hottest day must stay below about 19 °C for liquid storage. Fixed O&M is not modelled, because no sourced figure was found. Engineering, offsites and the first CO2 fill are excluded.
Model
126 variables — inputs, calculations and outputs, with their dependencies.
Model
126 variables — inputs, calculations and outputs, with their dependencies.
| Variable | Value | Unit | Depends on |
|---|---|---|---|
| 200 | MWh | — | |
| 10 | h | — | |
| 365 | cycles/year | — | |
| 1 | — | — | |
| 0 | — | — | |
| 150 | EUR/kWh | — | |
| 10 | t/MWh | — | |
| 70 | bar | — | |
| 25 | °C | — | |
| 3 | m | — | |
| 0.07 | ratio | — | |
| 30 | years | — |
| Variable | Formula | Unit | Depends on |
|---|---|---|---|
if((<=)+(<=)+(<=)+(<=)+(<=)+(<=)+(<)+(>=)+((+(-)*(-)/(-))>)+(**(+(/(*)))>)+(<)+(<)+(<)+(>)+(<)+(>)+(<=)>0,1,0) | bool |
| Variable | Formula | Unit | Depends on |
|---|---|---|---|
/max(,) | MW | ||
| t/MWh | ||
* | t | ||
if(<=,+(-)*(-)/(-),+(-)*(-)/(-)) | kg/m3 | ||
/max(,) | L/kg | ||
+(-)*(-)/(-) | bar | ||
- | bar | ||
- | °C | ||
*/max(,) | m3 | ||
/max(,) | m3/MWh | ||
(/-)* | % | ||
/max(*,) | m3/t | ||
* | m3 | ||
/max(,) | m3/MWh | ||
*^2**(+*) | m3 | ||
/max(,) | vessels | ||
ceil() | vessels | ||
- | bar | ||
max(+,*) | bar | ||
if(==,,) | MPa | ||
***/max(**-**,)+ | mm | ||
(/)/max(/,) | ratio | ||
*/max(*,) | ratio | ||
if((>)+(>)>0,1,0) | flag | ||
*(+/)*(+*)*(/)*/ | t | ||
*/ | lb | ||
if((<)+(>)>0,1,0) | flag | ||
exp(+*ln()+*ln()^2) | USD | ||
*// | EUR | ||
/max(*,) | EUR/kg | ||
* | t | ||
*/max(,) | t/MWh | ||
*/max(*,) | EUR/kWh | ||
* | EUR/kWh | ||
clamp(*(/)^(-),,) | EUR/kWh | ||
if(>=,,) | EUR/kWh | ||
if(>=,,/max(,)) | ratio | ||
*** | EUR | ||
/max(*,) | EUR/kWh | ||
/ | EUR | ||
- | EUR | ||
/max(,) | EUR/t | ||
/* | % | ||
* | h/year | ||
/(*) | ratio | ||
* | h/year | ||
/* | % | ||
* | MWh/year | ||
* | t/year | ||
/max(,) | t/h | ||
if(<,/,(*(+)^)/max((+)^-,)) | 1/year | ||
* | EUR/year | ||
*/max(,) | EUR/MWh | ||
*/max(,) | EUR/MWh | ||
+ | EUR/MWh |
Assumptions
67 assumptions used in the calculations
Assumptions
67 assumptions used in the calculations
Avoids a literal 0 in formulas.
Market range Not applicable.
0OpenJack DSL conventionAvoids a literal 1 in formulas.
Market range Not applicable.
1OpenJack DSL conventionConverts radius-based UG-27 to a diameter basis.
Market range Exact.
2GeometryCross-section of the shell.
Market range Exact.
0.25GeometryDisplay in percent.
Market range Exact.
100%Unit conversionMass conversion.
Market range Exact.
1000kg/tUnit conversionVolume conversion.
Market range Exact.
1000L/m3Unit conversionLength conversion.
Market range Exact.
1000mm/mUnit conversionPressure conversion for UG-27.
Market range Exact.
0.1MPa/barUnit conversionThe Seider cost correlation takes the vessel weight in lb.
Market range Exact.
0.453592kg/lbUnit conversionGauge pressure = absolute storage pressure minus one atmosphere.
Market range Exact.
1.01325barStandard atmosphereLower node of the density interpolation.
Market range Tabulated.
10.153°CNIST WebBookLiquid density at a cool site.
Market range Saturated liquid only; compressed liquid above saturation is a few percent denser (not credited).
859.99kg/m3NIST WebBookMiddle node of the interpolation.
Market range Tabulated.
25.038°CNIST WebBookDefault design density at a 25 °C maximum ambient.
Market range709.92kg/m3NIST WebBookLower node of the saturation-pressure line.
Market range Tabulated.
64.399barNIST WebBookUpper node of the interpolation.
Market range Tabulated.
30.022°CNIST WebBookLiquid density 1 °C below the critical point.
Market range Tabulated.
592.32kg/m3NIST WebBookHighest ambient temperature at which 70 bar still holds liquid.
Market range Tabulated.
28.611°CNIST WebBookUpper node of the saturation-pressure line, extrapolated linearly below 25 °C (slightly low by under 1 bar at 20 °C).
Market range Tabulated.
69.886barNIST WebBookNo liquid CO2 can exist above it: the calculator refuses a maximum ambient at or above it.
Market range 30.98 °C (NIST).
31°CEnergy Dome NETL 2022Leaves vapour space so thermal expansion of the liquid does not overfill the vessel.
Market range No independent range cited.
0.95ratio49 CFR 173.304bDesign pressure margin above the operating gauge pressure.
Market range No independent range cited.
1.1ratioBioSTEAM / SeiderMinimum design margin.
Market range No independent range cited.
2.068barBioSTEAM / SeiderReference case 1 allowable stress.
Market range103.4MPaBioSTEAM / SeiderReference case 2 allowable stress.
Market range No independent range cited.
137.9MPaASME II-D via secondary sourcesDocuments the source unit.
Market range Not applicable.
15000psiBioSTEAM / SeiderA 70 bar vessel of this thickness is fully radiographed.
Market range 0.85 spot radiography, 0.70 none.
1ratioASME VIII Div. 1 UW-12 via CheCalcAdded to the pressure thickness.
Market range3.175mmBioSTEAM / CheCalcCircumferential stress thickness.
Market range Exact.
1.2ASME UG-27Flags a design outside the thin-wall formula.
Market range Exact.
0.5ratioASME UG-27Flags a design outside the thin-wall formula.
Market range Exact.
0.385ratioASME UG-27Shell and heads mass.
Market range7861kg/m3IDAES / SeiderAdds the head steel to the shell.
Market range Exact within the method.
0.8ratioIDAES / SeiderUnit vessel length.
Market range12mIEEE Spectrum 2025 (indicative)Adds the head volume to the shell volume.
Market range Exact.
0.333333ratioGeometryPurchased cost of one vessel, incl. nozzles, manholes and supports.
Market range Valid 1,000-920,000 lb.
5.6336Seider 4th ed.Cost-weight elasticity.
Market range Exact within the method.
0.4599Seider 4th ed.Curvature of the cost-weight law.
Market range Exact within the method.
0.00582Seider 4th ed.Flags extrapolation.
Market range Exact.
1000lbSeider 4th ed.Flags extrapolation.
Market range Exact.
920000lbSeider 4th ed.Escalation base.
Market range Exact.
567Seider 4th ed.Escalates the 2013 correlation to 2023.
Market range Exact.
797.9CEPCI 2023Converts 2023 USD to 2023 EUR.
Market range Exact.
1.0813USD/EURECBTurns the f.o.b. vessel price into installed ISBL direct cost (erection, piping, instruments, electrical, civil, structures, lagging). Engineering, contingency and offsites are not included.
Market range No independent range cited.
3.2ratioTowler & Sinnott 2022Documents the largest term of the installation factor.
Market range No independent range cited.
0.8ratioTowler & Sinnott 2022Shows how the vessel bank compares with the whole-plant price: the model's vessel-only figure is already about 70 % of it, which says the conservative choices (S 15 ksi, generic factor 3.2, 70 bar) are high.
Market range No independent range cited.
220EUR/kWhEnergy-Storage.news 2023Reference size of the scale law.
Market range200MWhIEEE Spectrum 2025Numbering-up of identical vessels: the specific CAPEX per kWh does not change with plant size; whole-vessel rounding is shown separately.
Market range 1.0 for modular numbering-up; 0.6-0.7 only for a single larger vessel, which is outside this design.
1Seider 4th ed. / IEEE Spectrum 2025Prevents a degenerate value outside the domain.
Market range Not applicable.
10EUR/kWhOpenJack DSL conventionPrevents a degenerate value outside the domain.
Market range Not applicable.
2000EUR/kWhOpenJack DSL conventionReference case 1: Seider/BioSTEAM carbon steel, S = 15 ksi.
Market range Not applicable.
1OpenJack DSL conventionReference case 2: SA-516 Gr 70 at 20 ksi.
Market range Not applicable.
2OpenJack DSL conventionCharge power of the standard frame, used only to check that charge + discharge fit in the year.
Market range No independent range cited.
24MWEnergy Dome TMCES 2024Discharge power of the standard frame.
Market range No independent range cited.
18MWEnergy Dome TMCES 2024Charge energy = discharge / RTE; with 24/18 MW the charge then lasts 1.0 x the discharge.
Market range0.75ratioEnergy Dome 2024Default of the CO2 inventory slider (9-12 t/MWh).
Market range10t/MWhIEEE Spectrum 2025Benchmark for the CO2 inventory per MWh.
Market range Single plant.
10t/MWhIEEE Spectrum 2025Second benchmark for the CO2 inventory per MWh.
Market range Not applicable.
11.53t/MWhEnergy Dome NETL 2022 (derived)Inventory of the reference plant; the model returns 2,000 t at 200 MWh and 10 t/MWh by construction (not a validation).
Market range Single plant.
2000tIEEE Spectrum 2025Benchmark for the liquid specific volume.
Market range Not applicable.
1.3L/kgEnergy Dome NETL 2022Basis of the 15.0 m3/MWh liquid-volume benchmark.
Market range Not applicable.
66.7kWh/m3Energy Dome NETL 2022Benchmark for the liquid volume per MWh.
Market range Not applicable.
14.99m3/MWhEnergy Dome NETL 2022 (derived)Default of the storage pressure slider; a chain contract variable.
Market range70barEnergy Dome NETL 2022Default of the diameter slider.
Market range3mIEEE Spectrum 2025 (indicative)Scope: the liquid CO2 vessels only. The dome, compressor train, expander train and thermal storage are separate calculators. Chaining rule: the CO2 inlet comes from the charge compression train (upstream) and the CO2 outlet feeds the discharge expansion train (downstream) with the same yearly tonnage; link energy_capacity_mwh and co2_inventory_t one to one, never with a partial coefficient.
Market range Not applicable.
—OpenJack chain contractFixed O&M (inspection, recertification) is not modelled and exported as zero; add a project-level line if needed.
Market range No independent range cited.
—Research gap