Energy mass balanceCostingEquipment sizingStorage
CO2 battery charging train: compression with heat to the TES, from the atmospheric dome to liquid storage
Charging side of an Energy Dome-type CO2 battery: CO2 compressed from 1 atm to about 70 bar with its heat sent hot to the TES (about 440 °C), ambient condensation with an explicit feasibility limit, compressor CAPEX and service cost per tonne.
- CurrencyEUR 2023
- Battery limitinstalled
- 82 documented assumptions
- Updated2 Nov 2026
Mass and energy balance
What the asset draws and delivers for the case and load you choose.
Reference case
Full charge cycles a year (Girelli et al. 2025 use 300). The usage lever of the service cost.
Flows
- In: Electricity for charging—
- In: CO2 gas from the dome (1 atm)—
Asset
CO2 battery charging train (CO2 compression with heat to the TES, ambient condensation)
- Out: Liquid CO2 to storage vessels—
- Out: Compression heat to TES—
Annual quantities at the current usage. Band width: share of energy in; non-energy flows are not to scale.
Electric power drawn by the compressor train while charging. Energy Dome standard frame: 24 MWe compressor for an 18 MWe turbine and 200 MWh. Above 37 MW the model uses parallel motor trains.
- CO2 mass flow while charging
- — t/h
- Heat to TES
- — MW
- Heat rejected to dry coolers
- — MW
- CO2 moved per full charge
- — t
CAPEX
Specific cost at this size, what backs it, and how it behaves with scale.
Specific CAPEX at this size
—
Reference size 24 MW
Weiland et al. 2019
Model value: Weiland et al. 2019 integrally geared compressor law. Customized: enter a supplier quote for the compressor equipment; motor and installation are still added by the model.
Log in to view this sensitivity chart.
- Ex-factory
- Installed· this figure
- Fully financed
Included
- Equipment
- Installation, civil works and engineering
Not included
- Working capital
- Contingency
Added at project level
- Working capital layer, from the project settings
- Contingency, from the project settings
Project figures
Values passed to project mode when this asset is added to a project.
CO2 battery charging train (CO2 compression with heat to the TES, ambient condensation)Concept sketch, not to scale · drag to rotate
- Electricity for charging in
- —
- CO2 gas from the dome (1 atm) in
- —
- Liquid CO2 to storage vessels outMain product
- —
- Compression heat to TES out
- —
- CAPEX to the battery limit
- —
- Fixed O&M
- —
- Variable O&M, excluding feedstocks
- 0 EUR/year
- Asset lifetime
- 30 years
Log in to add this asset to a project.
Service cost per tonne liquefied
A standalone indicator for a quick read. Project mode recomputes it for the whole system.
—
- Service cost: capital—
- Service cost: O&M—
Linked to the balance above
Full charge cycles a year (Girelli et al. 2025 use 300). The usage lever of the service cost.
Hours of full-power charging per cycle. Energy Dome standard configuration: 24 MW for 10 h. Sets the CO2 moved per cycle and the heat stored per cycle.
Isentropic efficiency of the compression (of each stage in the intercooled cases). 85 % in Girelli et al. 2025 and Yan et al. 2023.
Temperature of the air used by the intercoolers and the dry-cooler condenser. Check condensation at the hot-season temperature: at 70 bar ambient condensation fails above about 26 °C (CO2 critical point 31 °C).
Pressure of the liquid CO2 vessels, which is also the compressor discharge pressure. Energy Dome stores at about 70 bar and ambient temperature. Must stay above the condensing pressure.
Real pre-tax discount rate for the standalone service cost (Girelli et al. 2025: 5 %). Project mode uses its own rate.
Annuity period of the service cost (Girelli et al. 2025: 30 years; Energy Dome: 30+ years).
Log in to view this sensitivity chart.
Benchmarks
This model's figures against published references and reference cases.
Condensing pressure, bar
34.85 NIST WebBook
54.65 NIST WebBook
68.92 NIST WebBook
73.8 McCollum & Ogden 2006
Reference cases at this size and usage
Log in to compare the reference cases.
All results
Every model output at the current settings, grouped, with the sensitivity charts.
46 outputs · 6 groups · 13 also shown above, dimmed
Service cost
6- Charging hours per year
- Computingh/year
- Charging capacity factor
- Computing%
Size and CAPEX
10- CAPEX per kW of charge power
- ComputingEUR/kW
- Motor cost per kW
- ComputingEUR/kW
- Installation cost per kW
- ComputingEUR/kW
- Compressor equipment
- ComputingEUR
- Drive motor(s)
- ComputingEUR
- Installation
- ComputingEUR
- Motor trains
- Computingtrains
- CAPEX per t/h of liquefaction
- ComputingEUR/(t/h)
Compression train
13- Electricity per tonne liquefied
- ComputingkWh/t
- Shaft work per tonne
- ComputingkWh/t
- CO2 mass flow (kg/s)
- Computingkg/s
- CO2 liquefied per MWh of charge
- Computingt/MWh
- Compression stages
- Computingstages
- Pressure ratio per stage
- Computing-
- Temperature rise per stage
- ComputingK
- Compressor discharge temperature
- Computing°C
- CO2 temperature after the TES on discharge
- Computing°C
- Ambient penalty on compressor work
- Computing%
- Shaft power
- ComputingMW
- Motor losses
- ComputingMW
Heat and condensation
10- Ambient condensation infeasible
- Computingflag
- Storage pressure above condensing pressure
- Computingbar
- Margin to the CO2 critical point
- ComputingK
- Condensing temperature
- Computing°C
- Condenser heat per tonne
- ComputingkWh/t
- Heat rejected per charge
- ComputingMWh
- Heat to TES per charge
- ComputingMWh
Charge cycle and yearly flows
4- Charging electricity per year
- ComputingMWh/year
- Heat to TES per year
- ComputingMWh/year
Finance
3- Capital recovery factor
- Computing1/year
- Annualised CAPEX
- ComputingEUR/year
Sensitivities
6 chartsLog in to view this sensitivity chart.
Log in to view this sensitivity chart.
Log in to view this sensitivity chart.
Log in to view this sensitivity chart.
Log in to view this sensitivity chart.
Log in to view this sensitivity chart.
Sources
82 documented assumptions · 10 sources
- swri.orgEnergy Dome (E. Watson), TMCES 202424 MWe compressor / 18 MWe turbine / 200 MWh standard frame (slide 14), TES outlet within 5 °C (slide 4), 225-250 USD/kWh plant claim (slide 18)
- doi.orgAstolfi, Rizzi, Macchi, Spadacini 2022, J. Eng. Gas Turbines Power (Energy Dome reference case)70 bar and 450 °C at the compressor exit, before the TES
- netl.doe.govEnergy Dome (J. Ferrari), TMCES 2022liquid CO2 at 70 bar and ambient temperature, critical temperature 31 °C
- energy-proceedings.orgYan et al. 2023, Energy Proceedings 30three-stage compression with heat-recovery coolers, condenser, liquid tank; pinch 5 K and 3 K
- itspubs.ucdavis.eduMcCollum & Ogden 2006, UCD-ITS-RR-06-14stage work equation, equal pressure ratio, R and M of CO2, five-stage CCS train
- osti.govWeiland, Lance, Pidaparti 2019, ASME GT2019-90493 (OSTI 1601743)integrally geared compressor and motor cost laws, installation 8 % + 12 %
- duepublico2.uni-due.deGirelli et al. 2025, 6th European sCO2 Conferenceefficiency 85 %, ambient 15 °C, CEPCI 2017/2023, 5 %, 30 years, O&M 1 %, 300 cycles
- webbook.nist.govNIST Chemistry WebBook, CO2 saturation table and 1 atm isobar (enthalpies, saturation pressure, Cp/Cv)
- data-api.ecb.europa.euECB, USD/EUR 2023 annual average 1.0813; ABB 2017 (motor efficiency 98.2-98.8 %)
- spectrum.ieee.orgIEEE Spectrum (E. Waltz, 21 Dec 2025)2,000 tonnes of CO2 in the dome, 20 MW over 10 hours
About
Calculator context
About
Calculator context
This calculator models the charging train of a CO2 battery (Energy Dome type). CO2 is drawn from the atmospheric dome and compressed to the liquid storage pressure (about 70 bar). The compression heat goes to the thermal store (TES). The CO2 is then condensed against ambient air in dry coolers and stored as a liquid at ambient temperature.
By default the compression has no cooling to ambient before the TES: the gas leaves the compressor hot and gives its heat to the TES, as in the Energy Dome reference case of Astolfi et al. 2022 (70 bar and 450 °C at the compressor exit). The model gives about 436 °C at 15 °C ambient, 119 kWh_e per tonne and about 2,020 t of CO2 per 24 MW x 10 h charge, against the 2,000 t that IEEE Spectrum (2025) reports for the 200 MWh Sardinia plant. Two intercooled trains stay available as alternative cases: three stages (Yan et al. 2023) and five stages (McCollum & Ogden 2006). They use less work but send much cooler heat (about 146 °C and 91 °C) to the TES.
The compression work uses an ideal-gas polytropic model with an equal pressure ratio per stage (McCollum & Ogden 2006). Cp/Cv comes from NIST: the mean Cp between 20 and 450 °C for the uncooled case, the value at 50 °C for the intercooled cases. Each stage takes its gas at ambient + 5 K, and the condenser works at ambient + 3 K (Yan et al. 2023). The condenser duty is the difference between NIST enthalpies of the gas at 1 atm and of the saturated liquid. The heat sent to the TES equals the shaft work, so the first-law balance closes. On discharge the CO2 leaves the TES 5 K below the compressor exit (Energy Dome 2024).
The condensation limit is explicit. The saturation pressure at the condensing temperature must stay below the storage pressure. At 70 bar ambient condensation fails above an ambient of about 26 °C, and the CO2 critical point (31 °C) is the absolute limit. A flag shows when a chiller would be needed; the chiller is not costed.
The CAPEX covers the compressor, its motor(s) and their installation. It uses the Weiland et al. 2019 DOE cost laws, escalated with CEPCI to 2023 EUR. This is a transposition, because those laws were fitted on high-inlet-pressure sCO2 compressors (evidence medium-low). Dry coolers, condenser and TES are excluded.
The service cost per tonne liquefied adds the annualised CAPEX and 1 % O&M (Girelli et al. 2025). It excludes the charging electricity, which the project prices as the asset's inlet.
Model
133 variables — inputs, calculations and outputs, with their dependencies.
Model
133 variables — inputs, calculations and outputs, with their dependencies.
| Variable | Value | Unit | Depends on |
|---|---|---|---|
| 24 | MW | — | |
| 10 | h | — | |
| 300 | cycles/year | — | |
| 1 | — | — | |
| 85 | % | — | |
| 15 | °C | — | |
| 70 | bar | — | |
| 0 | — | — | |
| 240 | EUR/kW | — | |
| 5 | % | — | |
| 30 | years | — |
| Variable | Formula | Unit | Depends on |
|---|---|---|---|
if((<=)+(<=)+(<=)+(*>)+(<=)+(>)+(<=)+(>=)+(+<)+(+>)+(<)+(>)+(<)+(>)+(<=)+(<)+(>)+(<)>,,) | bool | ||
/ | kJ/kg·K | ||
(-)/(-) | kJ/kg·K | ||
if(==,/(-),/) | - | ||
(-)/ | - | ||
/ | kJ/kg·K | ||
/ | - | ||
+ | °C | ||
** | kJ/kg | ||
(-)/ | kJ/kg·K | ||
+* | kJ/kg | ||
*^3+*^2+*+ | kJ/kg | ||
// | EUR2023/USD2017 | ||
** | MW | ||
*^*/(*) | EUR/kW | ||
* | ratio |
| Variable | Formula | Unit | Depends on |
|---|---|---|---|
if(==,,if(==,,)) | stages | ||
** | MW | ||
- | MW | ||
^(/) | - | ||
(+)*(^-)/(*) | K | ||
+ | °C | ||
- | °C | ||
/ | kWh/t | ||
/(*) | kWh/t | ||
((+)/(++)-)/ | % | ||
*/max(,) | t/h | ||
*/ | kg/s | ||
* | t | ||
/max(,) | t/MWh | ||
*/ | MW | ||
* | MWh | ||
+ | °C | ||
(-)/ | kWh/t | ||
*/ | MW | ||
* | MWh | ||
*^3+*^2+*+ | bar | ||
- | K | ||
- | bar | ||
if(<,,) | flag | ||
* | h/year | ||
// | % | ||
* | t/year | ||
* | MWh/year | ||
* | MWh/year | ||
(+)* | MWh/year | ||
if(>=,,clamp(*(/)^(-),,)) | EUR/kW | ||
** | EUR | ||
ceil(/) | trains | ||
**(/)^* | EUR | ||
(+)** | EUR | ||
++ | EUR | ||
/(*) | EUR/kW | ||
/(*) | EUR/kW | ||
/(*) | EUR/kW | ||
/max(,) | EUR/(t/h) | ||
if(<,/,(*(+)^)/max((+)^-,)) | 1/year | ||
* | EUR/year | ||
** | EUR/year | ||
/max(,) | EUR/t | ||
/max(,) | EUR/t | ||
+ | EUR/t |
Assumptions
82 assumptions used in the calculations
Assumptions
82 assumptions used in the calculations
Lower limit in the input guards and the feasibility flag.
0Numerical constantUnit multiplier in the CRF, the guards and the Customized switch.
1Numerical constantUpper limit of a percentage in the input guards.
100%Numerical constantConverts a percentage (0-100) to a fraction.
0.01Unit conversionConverts MW to kW (and kW to MW by division).
1000kW/MWUnit conversionConverts tonnes to kilograms for the mass flow in kg/s.
1000kg/tUnit conversionConverts degrees Celsius to kelvin in the stage temperature rise.
273.15KUnit conversion1 kWh/t = 3,600 kJ / 1,000 kg = 3.6 kJ/kg; converts specific work and enthalpy differences to kWh/t.
3.6kJ/kg per kWh/tUnit conversionValue of the technology_case select for the default case.
1Selector identifierValue of the technology_case select for the three-stage case.
2Selector identifierValue of the technology_case select for the five-stage case.
3Selector identifierDefault case: one compression section from 1 atm to the storage pressure, no cooling to ambient before the TES. This is what sends the heat to the TES hot, as the Energy Dome reference case does.
1stagesAstolfi et al. 2022Stage count of the three-stage intercooled alternative. Yan's system (atmospheric holder, compression with heat-recovery coolers, condenser, liquid tank) intercools to ambient + 5 K, so its heat reaches the TES at about 146 °C only.
3stagesYan et al. 2023Stage count of the CCS-style case: more stages, closer to isothermal, lower work and a cooler discharge, so less useful heat for the TES.
5stagesMcCollum & Ogden 2006Reference size of the scale law (the Energy Dome standard compressor frame). The Weiland law is written as a ratio to this size; the result is identical to the absolute correlation.
24MWEnergy Dome TMCES 2024Suction pressure of the first stage.
1.01325barEnergy Dome TMCES 2024 / NISTAbove this condensing temperature no liquid can form at any pressure; the condensation margin is measured against it. NIST gives 30.98 °C.
31°CEnergy Dome TMCES 2022Upper guard on the storage pressure: the liquid store must stay subcritical. Also a benchmark for the condensing pressure.
73.8barMcCollum & Ogden 2006Temperature the CO2 regains from the TES on discharge = compressor discharge temperature minus 5 K. Vendor statement, not a measured approach temperature.
5KEnergy Dome TMCES 2024Each intercooler returns the gas to ambient + 5 K before the next stage.
5KYan et al. 2023The CO2 condenses at ambient + 3 K against the dry coolers.
3KYan et al. 2023Electric-to-shaft efficiency of the drive motor. The motor losses are counted in the heat and losses output.
98.2%ABB 2017Universal gas constant for the ideal-gas compression work.
8.314kJ/kmol·KMcCollum & Ogden 2006Molar mass of CO2; R/M = 0.18892 kJ/kg·K.
44.01kg/kmolMcCollum & Ogden 2006Numerator of the heat-capacity ratio k = Cp/Cv (1.282) used in the polytropic group (k-1)/k.
0.87453kJ/kg·KNIST WebBookDenominator of the heat-capacity ratio. Taken at 1 atm and 50 °C, inside the stage temperature range; the real-gas departure of the last stage is discussed in scope_real_gas_crosscheck.
0.68215kJ/kg·KNIST WebBookFirst point of the linear gas-enthalpy line at 1 atm.
484.87kJ/kgNIST WebBookSecond point of the linear gas-enthalpy line; slope 0.85082 kJ/kg·K.
527.41kJ/kgNIST WebBookLow end of the mean Cp used for the uncooled case: Cp_mean = (h(450 °C) - h(20 °C)) / 430 K = 1.0111 kJ/kg·K, then k = Cp/(Cp - R) = 1.230.
501.6kJ/kgNIST WebBookHigh end of the mean Cp of the uncooled case, at the 450 °C compressor exit of Astolfi et al. 2022. Taken at 1 atm (ideal-gas part); the real-gas departure at 70 bar and high temperature is small and not modelled.
936.36kJ/kgNIST WebBookUpper end of the temperature span of the mean Cp (20-450 °C) for the uncooled case, and the published reference against which the computed discharge temperature is read.
450°CAstolfi et al. 2022Lower end of the mean-Cp span (about ambient + 5 K at the 15 °C default).
20°CNIST WebBookTemperature span of the linear gas-enthalpy line (0 to 50 °C).
50°CNIST WebBookCubic term of the saturated-liquid enthalpy fit. Max error 0.6 kJ/kg on 0-28 °C (checked: 289.05 against NIST 289.62 at 28 °C, 249.05 against 249.26 at 18 °C).
0.001536kJ/kg·K³Fit to NISTQuadratic term of the saturated-liquid enthalpy fit.
-0.025754kJ/kg·K²Fit to NISTLinear term of the saturated-liquid enthalpy fit.
2.708088kJ/kg·KFit to NISTConstant term of the saturated-liquid enthalpy fit (h at 0 °C).
199.6866kJ/kgFit to NISTCubic term of the saturation-pressure fit. Max error 0.008 bar on 0-28 °C (34.846 against 34.851 at 0 °C, 54.649 against 54.651 at 18 °C, 68.910 against 68.918 at 28 °C).
0.000073bar/K³Fit to NISTQuadratic term of the saturation-pressure fit.
0.008269bar/K²Fit to NISTLinear term of the saturation-pressure fit.
0.927551bar/KFit to NISTConstant term of the saturation-pressure fit (psat at 0 °C).
34.84566barFit to NISTGuard: a condensing temperature below 0 °C is outside the fitted range and is refused.
0°CModel domainGuard: a condensing temperature above 28 °C is outside the fitted range and close to the critical point; it is refused. With the 3 K condenser pinch this caps the ambient at 25 °C.
28°CModel domainReference ambient of the load penalty: the compressor work is compared with the same train at 15 °C.
15°CGirelli et al. 2025Coefficient of the integrally geared centrifugal compressor cost law. Transposed: the correlation is fitted on sCO2 compressors with an inlet at 65-90 bar, here the inlet is at 1 bar.
1230000USD2017Weiland et al. 2019Scale exponent of the compressor cost on its shaft power: specific cost falls as size^(0.3992-1). Sourced to a DOE cost-data regression; evidence medium because the low-pressure CO2 duty is a transposition.
0.3992Weiland et al. 2019Coefficient of the drive-motor cost law.
399400USD2017Weiland et al. 2019Scale exponent of the motor cost.
0.6062Weiland et al. 2019Largest single motor the law covers. Above it the model uses parallel motor trains of equal size, as Energy Dome does with its double-compressor layout.
37MWWeiland et al. 2019Installation on top of the bare equipment cost (Weiland's correlations are equipment costs).
20%Weiland et al. 2019Cost index of the Weiland base year.
567.5Girelli et al. 2025Cost index of the 2023 reporting year.
800.8Girelli et al. 2025Converts 2023 USD to 2023 EUR after CEPCI escalation.
1.0813USD/EURECBFixed O&M of the compression train per year. Girelli applies it to the whole plant; applied here to the compressor train.
1%/yearGirelli et al. 2025Lower clamp of the scaled compressor specific CAPEX. Checked at the slider ends (3 and 135 MW): it never binds.
20EUR/kWModel guardUpper clamp of the scaled compressor specific CAPEX. Checked at the slider ends: it never binds.
3000EUR/kWModel guardBenchmark for the condensing pressure at a cold site.
34.851barNIST WebBookBenchmark for the condensing pressure at the 15 °C nominal ambient (T_cond 18 °C).
54.651barNIST WebBookBenchmark at the hottest ambient the model accepts (25 °C, T_cond 28 °C): 1.1 bar below the 70 bar storage pressure.
68.918barNIST WebBookCheck point of the liquid enthalpy fit (fit gives 249.05).
249.26kJ/kgNIST WebBookCheck point of the liquid enthalpy fit (fit gives 289.05).
289.62kJ/kgNIST WebBookDischarge side of the reference frame; not used by this charging calculator, given for chaining with the turbine calculator.
18MWEnergy Dome TMCES 2024Whole-plant vendor claim, used only as a qualitative ceiling: see scope_vendor_claim_comparison.
225USD/kWhEnergy Dome TMCES 2024Upper end of the vendor whole-plant claim.
250USD/kWhEnergy Dome TMCES 2024Default charge power 24 MW = the Energy Dome standard compressor frame (24 MWe compressor, 18 MWe turbine, 200 MWh, 10 h). The chain contract range is 2.5-100 MW of discharge, about 3-135 MW of charge.
—UnspecifiedDefault 10 h of charging per cycle: '24MW/10h' charging in the Energy Dome standard configuration. The chain contract range is 4-24 h.
—UnspecifiedDefault 300 full cycles a year, the Girelli et al. 2025 case (section 5). The usage lever of the service cost.
—UnspecifiedDefault isentropic efficiency 85 % (of the compression in the default case, of each stage in the intercooled cases): Girelli et al. 2025 Table 1 ('Compressor isentropic efficiency 85%') and Yan et al. 2023 Table 1 (0.85). Slider 80-90 %.
—UnspecifiedDefault ambient 15 °C (Girelli et al. 2025, Table 1). The input binds to the site mean temperature; condensation feasibility must also be checked at the site's hot-season temperature. Slider 0-25 °C: above 25 °C the condensing temperature leaves the fitted NIST range and approaches the 31 °C critical point.
—UnspecifiedDefault liquid storage pressure 70 bar: Energy Dome TMCES 2022 slide 4 (CO2 storage 'High (70 bar)', temperature 'CO2 = Ambient'). Slider 65-73 bar, below the 73.8 bar critical pressure.
—UnspecifiedDefault discount rate 5 % and economic life 30 years (Girelli et al. 2025, section 4.2; Energy Dome TMCES 2024 slide 18 '30+ y'). The rate is real: all costs are constant 2023 EUR, nothing is escalated.
—UnspecifiedCompression work is computed with an ideal-gas polytropic model per stage (McCollum & Ogden 2006 stage equation with Z = 1): stage temperature rise = T_in (r^((k-1)/k) - 1) / eta_is, work = N cp dT. Uncooled default case: k = 1.230 from the NIST mean Cp between 20 and 450 °C at 1 atm (Cv = Cp - R). Intercooled cases: k = 1.282 from NIST Cp/Cv at 1 atm and 50 °C. Equal pressure ratio per stage.
—UnspecifiedEvery stage, the first one included, takes its gas at ambient + 5 K. The first stage actually draws from the dome at about ambient, so the work is overstated by about 1.7 % at 15 °C: a conservative simplification.
—UnspecifiedFirst-law split for an ideal gas: enthalpy depends on temperature only, so all shaft work leaves as sensible heat when the gas is cooled back to the stage inlet temperature. Heat to TES = shaft power. The condenser and dry coolers reject h_gas(1 atm, T_in) - h_liq,sat(T_cond) from NIST. The balance W_sh + m h_in = m h_liq + Q_TES + Q_rej closes by construction. In the default case all of this heat leaves the compressor at about 436 °C; in the intercooled cases it is at 91-146 °C. How much the TES can store usefully is the TES calculator's question, not this one's.
—UnspecifiedReal-gas cross-check: McCollum & Ogden 2006 use per-stage Z and k (stage 5: Z = 0.845, k = 1.704). The research step ran their equation at N = 5, eta 85 %, T_in 20 °C and got 81.5 kWh/t of shaft work; this model gives 84.3 kWh/t at the same point (+3 %). The 81.5 is a computation with McCollum's equation, not a figure printed in the report.
—UnspecifiedCondensation feasibility is explicit: the CO2 condenses at ambient + 3 K against dry coolers. If the saturation pressure at that temperature exceeds the storage pressure, ambient condensation is impossible without a chiller or water cooling (not modelled, not costed) and the flag shows 1. At 70 bar this happens above about 26 °C ambient; at 65 bar above about 21.5 °C. The critical point (31 °C, 73.8 bar) is the absolute limit.
—UnspecifiedScope exclusion: the dry coolers, the condenser and the TES are NOT in the CAPEX. Weiland's dry-cooler law (32.88 UA^0.75) needs a UA that would rest on an unsourced air-side temperature difference. The CAPEX is the compressor, its motor(s) and their installation only.
—UnspecifiedThe Weiland integrally geared compressor law is fitted on sCO2 compressors with an inlet at 65-90 bar (uncertainty -39 %/+48 %). Here the inlet is at 1 bar, so the large low-pressure volumetric flow makes it a transposition: evidence medium-low. The Hendriks CCS compression law quoted by McCollum & Ogden 2006 gives about 1,450 USD(2005)/kW at 24 MW before escalation, an upper envelope that would exceed the vendor whole-plant claim per kW of compressor.
—UnspecifiedQualitative comparison only: Energy Dome claims 225-250 USD/kWh for the whole plant (TMCES 2024, 2024 USD), about 45-50 M USD for 200 MWh, i.e. roughly 1,900-2,100 USD per kW of compressor. The modelled compressor train (2023 EUR) is roughly a fifth to a quarter of that. The currency years differ and no 2024 rate is cited, so no position is concluded beyond 'well below the whole-plant claim'.
—UnspecifiedChain-contract anchor: IEEE Spectrum (E. Waltz, 21 Dec 2025) reports '2,000 tonnes of carbon dioxide' in the Sardinia dome and '20 MW over 10 hours' (200 MWh). The default case gives 201.7 t/h, i.e. about 2,017 t per 24 MW x 10 h charge (+0.8 %) at 119.0 kWh_e/t. This is an independent check: the 2,000 t enters no node. The intercooled cases give 2,622 t (three stages) and 2,797 t (five stages), 31-40 % above: the TES and discharge calculators should be chained to the default case.
—UnspecifiedService cost = (annualised CAPEX + fixed O&M) / tonnes liquefied per year. It excludes the value of the charging electricity: the electricity is the inlet of the asset and the project prices it; counting it here would double count. No revenue, tax or subsidy. Constant 2023 EUR, real discount rate.
—UnspecifiedCorners of the input box (cases 1-3, efficiency 80-90 %, ambient 0-25 °C, storage pressure 65-73 bar): specific electricity 75.4-132.6 kWh_e/t (top end: uncooled case, 80 %, 25 °C, 73 bar); compressor exit 67-494 °C (above 450 °C the mean Cp is a short extrapolation); condenser heat 61.5-78.2 kWh_th/t; condensing pressure 37.7-68.9 bar. CAPEX 369-732 EUR/kW over 10-37 MW of charge power; below 10 MW it rises above the stored bound (about 824 EUR/kW at 3 MW), above 37 MW parallel motors bring it to about 260-370 EUR/kW. The service cost spans about 0.08-97 EUR/t over all corners of size, duration, cycles and finance; the stored bound covers the nominal case and the plotted sweeps.
—Unspecified