Sodium-ion stationary battery storage (containerised): LCOS, round-trip efficiency and degradation

Grid-connected sodium-ion battery containers from 2 to 500 MWh: LCOS in EUR/MWh delivered after the PNNL 2024 method with Keiner et al. 2026 costs, round-trip efficiency, linear capacity fade to 80 % and service life, by reference case.

  • CurrencyEUR 2024
  • Battery limitinstalled
  • 63 documented assumptions
  • Updated27 Oct 2026

Mass and energy balance

What the asset draws and delivers for the case and load you choose.

Reference case

Full cycles a year over the usable energy. 365 is the NREL ATB 2025 duty of about one cycle a day. Fewer cycles stretch the cycle-limited life until the calendar life caps it. The slider stops at 340: below, the conservative 2-hour case leaves the sourced LCOS envelope.

Flows

  • In: Electricity for charging—

Asset

Sodium-ion stationary battery storage (containerised)

  • Out: Electricity discharged—

Annual quantities at the current usage.

Usable energy of the sodium-ion plant (Keiner et al. convention: per kWh of usable capacity). The catalogue binds products here: Salzstrom SALT BESS 2.3 MWh, Peak Energy Grid Storage 1 at 3.1 MWh. Costs are linear in size; below about 10 MWh the per-kWh cost is an extrapolation of a utility-scale figure and is probably too low (flag shown).

Rated power
— MW
Energy delivered
— MWh/a
Energy delivered over the service life
— MWh

CAPEX

Specific cost at this size, what backs it, and how it behaves with scale.

Specific CAPEX at this size

—

Reference size 100 MWh

Keiner et al. 2026, Table 4 (linear)

Model value: Keiner et al. 2026 energy and power costs at your duration. Customized: your own quote per kWh of usable energy, used as is at every size; the value is then no longer sourced.

CAPEX per kWh by energy capacity (usable)

Log in to view this sensitivity chart.

  1. Ex-factory
  2. Installed· this figure
  3. Fully financed
CAPEX at the battery limit—
Working capital, contingencyproject level

Included

  • Equipment
  • Installation, civil works and engineering

Not included

  • Working capital
  • Contingency

Added at project level

  • Working capital layer, from the project settings
  • Contingency, from the project settings

Project figures

Values passed to project mode when this asset is added to a project.

Concept sketch, not to scale · drag to rotate

Electricity for charging in
—
Electricity discharged outMain product
—
CAPEX to the battery limit
—
Fixed O&M
—
Variable O&M, excluding feedstocks
0 EUR/year
Asset lifetime
12 years

Log in to add this asset to a project.

LCOS excluding charging

A standalone indicator for a quick read. Project mode recomputes it for the whole system.

—

  • LCOS: capital—
  • LCOS: fixed O&M—

Linked to the balance above

Full cycles a year over the usable energy. 365 is the NREL ATB 2025 duty of about one cycle a day. Fewer cycles stretch the cycle-limited life until the calendar life caps it. The slider stops at 340: below, the conservative 2-hour case leaves the sourced LCOS envelope.

Hours of discharge at rated power. Rated power = usable energy / duration. The power interface cost is per kW, so short durations cost more per kWh.

Average price of the charging electricity, only used in the LCOS including charging. Default: German day-ahead average 2024, 78.51 EUR/MWh (Bundesnetzagentur), a conservative upper reference since storage charges in low-price hours.

Real rate of the capital recovery factor, because all costs are constant 2024 EUR. Default 6.49 %, derived from the PNNL 2024 financing parameters (8 % debt, 13 % equity, 50 % debt, 25.7 % tax, 2.8 % inflation). The slider spans 5.5-6.5 % around that value, the rate at which the cited LCOS envelope holds. A zero rate is handled (CRF = 1/n).

Lowest ambient temperature expected at the site. Compared with the cell working ranges of IRENA 2025 (sodium-ion -40 °C, Li-ion -20 °C). An indicator only: it changes no cost.

LCOS excluding charging by cycles per year

Log in to view this sensitivity chart.

Benchmarks

This model's figures against published references and reference cases.

Round-trip efficiency (AC), %

85 NREL ATB 2025

90 Keiner et al. 2026, §2.3

92 IRENA 2025, Table 2

Reference cases at this size and usage

Log in to compare the reference cases.

All results

Every model output at the current settings, grouped, with the sensitivity charts.

53 outputs · 6 groups · 11 also shown above, dimmed

Levelised cost

7
LCOS excluding charging
ComputingEUR/MWh
LCOS: capital
ComputingEUR/MWh
LCOS: fixed O&M
ComputingEUR/MWh
Capital share of the LCOS
Computing%
LCOS with NREL fixed O&M
ComputingEUR/MWh
LCOS: charging
ComputingEUR/MWh
LCOS including charging
ComputingEUR/MWh

Size and CAPEX

15
Rated power
ComputingMW
Total installed CAPEX
ComputingEUR
CAPEX per kWh
ComputingEUR/kWh
Model CAPEX per kWh (scaled)
ComputingEUR/kWh
Model CAPEX per kWh at reference size
ComputingEUR/kWh
Cell CAPEX per kWh
ComputingEUR/kWh
System periphery CAPEX per kWh
ComputingEUR/kWh
Power interface cost
ComputingEUR/kW
Power interface CAPEX per kWh
ComputingEUR/kWh
Energy share of CAPEX
Computing%
Energy-related CAPEX
ComputingEUR
Cell CAPEX
ComputingEUR
Power-related CAPEX
ComputingEUR
CAPEX per kW
ComputingEUR/kW
Size extrapolation flag
Computingflag

Energy balance

9
Round-trip efficiency (AC)
Computing%
Energy delivered
ComputingMWh/a
Energy charged
ComputingMWh/a
Heat and losses
ComputingMWh/a
Charging energy per MWh delivered
ComputingMWh/MWh
Discharge full-load hours
Computingh/a
Discharge capacity factor
Computing%
Energy delivered over the service life
ComputingMWh
Average delivered power
ComputingMW

Degradation and life

11
End-of-life capacity
Computing%
Mean capacity retention
Computing%
Degradation penalty on energy
Computing%
Capacity fade per cycle
Computing%/cycle
Cycle life to 80 %
Computingcycles
Calendar life
Computingyears
Cycle-limited life
Computingyears
Service life
Computingyears
Cycle-limited life flag
Computingflag
Full cycles over the service life
Computingcycles
Duty against one cycle a day
Computing%

Cold climate

3
Margin to the sodium-ion cold limit
Computing°C
Within sodium-ion cold range
Computingflag
Within Li-ion cold range
Computingflag

Finance and yearly costs

8
PNNL nominal WACC
Computing%
PNNL real WACC
Computing%
Capital recovery factor
Computing1/year
Annualised CAPEX
ComputingEUR/year
Fixed O&M
ComputingEUR/year
Fixed O&M, NREL sensitivity
ComputingEUR/year
Yearly cost excluding charging
ComputingEUR/year
Yearly charging cost
ComputingEUR/year

Sensitivities

6 charts
LCOS components vs cycles per year

Log in to view this sensitivity chart.

LCOS components by storage duration

Log in to view this sensitivity chart.

CAPEX per kWh and total CAPEX vs energy capacity

Log in to view this sensitivity chart.

End-of-life capacity and service life vs cycles per year

Log in to view this sensitivity chart.

LCOS including charging vs charging price

Log in to view this sensitivity chart.

Round-trip efficiency by reference case

Log in to view this sensitivity chart.

About

Calculator context

Containerised sodium-ion battery plant (NFPP or layered-oxide cathode, hard-carbon anode) connected to the grid. You set the usable energy (2 to 500 MWh), the duration (2 to 8 h) and the full cycles a year, and pick a reference case that fixes the round-trip efficiency, calendar life, cycle life to 80 % and power interface cost. The CAPEX follows Keiner et al. 2026 (Journal of Energy Storage 146): an energy-related cost of 116.3 EUR2024 per kWh of usable capacity (75 % cells, 25 % periphery) plus a power interface of 135 EUR/kW, or 400 EUR/kW in the conservative case, the upper end of the 150-400 EUR/kW Keiner cites from other studies. Costs are linear in size: containers are modular and no economy of scale is sourced, so the LCOS does not depend on size. Below about 10 MWh, where the catalogue products sit (Salzstrom SALT BESS 2.3 MWh, Peak Energy Grid Storage 1 at 3.1 MWh), the per-kWh cost is an extrapolation of a utility-scale figure, probably too low, and a flag says so.

Degradation is linear per cycle down to 80 % at the IRENA 2025 cycle life (4,000 to 5,000 cycles). The service life is the shorter of the calendar life and the cycle life divided by the cycles a year (PNNL 2024, Eq. 5); no replacement or augmentation is costed, and calendar fade is not modelled separately because no citable value exists for sodium-ion cells. The levelised cost of storage is a simplified PNNL 2024 LCOS: CAPEX annualised at a real rate over the service life plus a fixed O&M of 1.7 % of CAPEX a year (Keiner), per mean MWh delivered. The headline excludes charging, as Keiner does; a second figure adds the charging price divided by the round-trip efficiency. The default real rate, 6.49 %, is derived from the PNNL financing parameters, not printed by PNNL.

At 100 MWh, 4 h, one cycle a day and the central case, the plant costs 150 EUR/kWh (15.0 MEUR), lasts about 12.3 years (cycle-limited), delivers 32,850 MWh a year on average and gives an LCOS of about 63 EUR/MWh excluding charging, about 150 EUR/MWh with charging at the 2024 German day-ahead average of 78.51 EUR/MWh, a conservative reference since storage charges in low-price hours. The NREL ATB fixed O&M of 4 % is shown as a sensitivity. A cold-climate indicator compares the site minimum temperature with the IRENA cell ranges (-40 °C sodium-ion, -20 °C Li-ion). No revenue, tax or subsidy: those belong to project mode.

Model

109 variables — inputs, calculations and outputs, with their dependencies.

109 variables shown of 109
VariableValueUnitDepends on
100MWh—
4h—
365cycles/year—
1——
0——
150EUR/kWh—
78.51EUR/MWh—
6.49%—
-10°C—
VariableFormulaUnitDepends on
if((<=)+(<=)+(<=)+(<)+(>)+(<)+(>)+(<=)+(<)+(<)+(>)+(**(+/(*))>)>,,)bool
*kW
*kWh
*ratio
if(>=,,)—
*ratio
VariableFormulaUnitDepends on
if(==,,if(==,,))%
if(==,,)years
if(==,,if(==,,))cycles
if(==,,)EUR/kW
/max(,)MW
/max(,)years
min(,)years
if(<,,)flag
(-)/max(,)%/cycle
*cycles
-*%
(+)/%
-%
/(*)*%
***MWh/a
/max(,)h/a
/*%
/max(,)MWh/a
-MWh/a
/max(,)MWh/MWh
*MWh
/MW
**EUR/kWh
-EUR/kWh
/max(,)EUR/kWh
++EUR/kWh
clamp(*(/)^(-),,)EUR/kWh
if(>=,,)EUR/kWh
*EUR
/max(,)*%
**EUR
-EUR
**EUR
/max(,)EUR/kW
if(<,,)flag
***(-*)+(-*)*%
((+*)/(+*)-)*%
if(<,/max(,),(*(+)^)/max((+)^-,))1/year
*EUR/year
**EUR/year
**EUR/year
+EUR/year
*EUR/year
/max(,)EUR/MWh
/max(,)EUR/MWh
+EUR/MWh
/max(,)EUR/MWh
+EUR/MWh
/max(,)*%
(+)/max(,)EUR/MWh
-°C
if(>=,,)flag
if(>=,,)flag

Assumptions

63 assumptions used in the calculations

  • Lower limit in the input guards.

    Market range Exact by definition.

    0
    Numerical constant
  • Unit multiplier in the CRF, the guards and the Customized switch.

    Market range Exact by definition.

    1
    Numerical constant
  • Divisor of the mean of the beginning-of-life and end-of-life capacity (linear fade).

    Market range Exact by definition.

    2
    Numerical constant
  • Protects divisions against a zero denominator.

    Market range Exact by definition.

    0
    Numerical constant
  • Converts a percent into a fraction.

    Market range Exact by definition.

    0.01
    Numerical constant
  • Converts a fraction into a percent; also the 100 % beginning-of-life capacity.

    Market range Exact by definition.

    100
    Numerical constant
  • kWh per MWh.

    Market range Exact by definition.

    1000
    Numerical constant
  • kW per MW.

    Market range Exact by definition.

    1000
    Numerical constant
  • Hours in a non-leap year; feasibility guard and capacity factor.

    Market range Exact by definition.

    8760
    Numerical constant
  • Days in a non-leap year; one-cycle-a-day reference duty.

    Market range Exact by definition.

    365
    Numerical constant
  • Integer code of the reference case 'Keiner et al. 2026 central case' in the technology_case select.

    Market range Identifier only.

    1
    Selector code
  • Integer code of the reference case 'IRENA 2025 favourable case' in the technology_case select.

    Market range Identifier only.

    2
    Selector code
  • Integer code of the reference case 'Conservative envelope of the cited ranges' in the technology_case select.

    Market range Identifier only.

    3
    Selector code
  • Energy-related CAPEX of the sodium-ion storage system per kWh of usable energy (cells plus system periphery). It is the same figure in all three reference cases: only the power interface, life and efficiency change between cases.

    Market range No independent European range cited in the same boundary; Chinese tenders (1.035 CNY/Wh bid, 1.1 CNY/Wh ceiling) are of the same order but their scope (PCS, EPC) is not stated.

    116.3EUR/kWh
    Keiner et al. 2026, Table 4
  • Splits the energy-related CAPEX into cells and periphery for the breakdown. It changes no total.

    Market range No independent split cited.

    75%
    Keiner et al. 2026, §3.2
  • Power interface (inverter / PCS) cost per kW of rated power in the central and favourable cases. Divided by the duration it becomes a per-kWh adder, so short durations cost more per kWh.

    135EUR/kW
    Keiner et al. 2026, §3.2
  • Power interface cost of the conservative case, the upper end of the range cited by Keiner et al.

    400EUR/kW
    Keiner et al. 2026, §3.2
  • Yearly fixed O&M as a share of CAPEX, in all three cases. It contains no augmentation: the capacity fades and the energy delivered falls with it.

    Market range 1.7 % (Keiner) to 4 % (NREL ATB 2025, Li-ion, augmentation included).

    1.7%
    Keiner et al. 2026, Table 4
  • Alternative fixed O&M for the sensitivity output 'LCOS with NREL fixed O&M'. It is not used in the headline LCOS.

    Market range 1.7 % (Keiner) to 4 % (NREL ATB 2025).

    4%
    NREL ATB 2025
  • Calendar life of the central and favourable cases: the service life is the shorter of this and the cycle life divided by the cycles a year (PNNL Eq. 5).

    15years
    Keiner et al. 2026, Table 4
  • Calendar life of the conservative case.

    10years
    IRENA 2025, Table 2
  • AC round-trip efficiency of the central case.

    Market range 85 % (NREL ATB 2025, Li-ion) to 92 % (IRENA 2025, SIB).

    90%
    Keiner et al. 2026, §2.3
  • Round-trip efficiency of the favourable case.

    92%
    IRENA 2025, Table 2
  • Round-trip efficiency of the conservative case.

    85%
    NREL ATB 2025
  • Full cycles until the usable energy falls to 80 % in the central case.

    Market range 4 000-5 000 cycles to 80 % (IRENA 2025, §3.3); IRENA Table 2 gives 500-8 000 across all SIB chemistries.

    4500cycles
    IRENA 2025, §3.3
  • Cycle life of the conservative case.

    Market range 4 000-5 000 cycles to 80 % (IRENA 2025, §3.3).

    4000cycles
    IRENA 2025, §3.3
  • Cycle life of the favourable case.

    Market range 4 000-5 000 cycles to 80 % (IRENA 2025, §3.3).

    5000cycles
    IRENA 2025, §3.3
  • End-of-life threshold: the linear fade per cycle is (100 - 80) % divided by the cycle life.

    Market range 80 % is the usual warranty and PNNL replacement threshold.

    80%
    PNNL LCOS Workbook 2024, Eq. 5
  • Reference duty of one full cycle a day, used for the duty ratio output.

    Market range One cycle a day is the usual utility-scale reference.

    1cycles/day
    NREL ATB 2025
  • Debt rate in the PNNL WACC formula (p.4).

    Market range No independent European range cited.

    8%
    PNNL LCOS Workbook 2024, §2.5
  • Cost of equity in the PNNL WACC formula.

    Market range No independent European range cited.

    13%
    PNNL LCOS Workbook 2024, §2.5
  • Debt share in the PNNL WACC formula.

    Market range No independent European range cited.

    50%
    PNNL LCOS Workbook 2024, §2.5
  • Tax rate of the debt tax shield in the PNNL WACC formula. No other tax is modelled.

    Market range No independent European range cited.

    25.7%
    PNNL LCOS Workbook 2024, §2.5
  • Converts the nominal PNNL WACC into the real rate used with constant 2024 EUR.

    Market range No independent European range cited.

    2.8%
    PNNL LCOS Workbook 2024, §2.5
  • Lowest working temperature of sodium-ion cells, compared with the site minimum temperature in the cold-climate indicator.

    Market range -40 °C (SIB) against -20 °C (Li-ion), IRENA 2025, Table 2.

    -40°C
    IRENA 2025, Table 2
  • Lowest working temperature of Li-ion cells, for the comparison flag only.

    Market range -20 °C (Li-ion), IRENA 2025, Table 2.

    -20°C
    IRENA 2025, Table 2
  • Exponent 1: the cost scales linearly with capacity. Containerised battery storage is modular (numbering-up of identical containers) and Keiner et al. give a single per-kWh capex without a size range, so no economy of scale is sourced. Below about 10 MWh this probably underestimates the cost per kWh (fixed project costs are not spread): the calculator flags that range as an extrapolation instead of inventing a scaling law.

    Market range No sourced exponent for sodium-ion BESS.

    1
    Keiner et al. 2026, Table 4 (linear)
  • Reference size of the scaling formula. Keiner et al. publish no plant size, so the nominal 100 MWh case is used; with an exponent of 1 it has no effect.

    Market range Not applicable.

    100MWh
    Authoring choice
  • Lower clamp of the scaled specific CAPEX; never reached inside the declared domain.

    Market range Model domain 133-316 EUR/kWh.

    50EUR/kWh
    Numerical guard
  • Upper clamp of the scaled specific CAPEX; never reached inside the declared domain.

    Market range Model domain 133-316 EUR/kWh.

    2000EUR/kWh
    Numerical guard
  • Below this size the extrapolation flag is raised: the linear cost model probably underestimates the cost per kWh of a single container.

    Market range No sourced threshold.

    10MWh
    Authoring threshold
  • Usable energy of the plant. All cycling is 100 % depth of discharge of this usable energy.

    100MWh
    Input default
  • Rated power = usable energy / duration.

    4h
    Input default
  • Full cycles a year at 100 % depth of the usable energy; the usage lever of the page.

    365cycles/year
    Input default
  • Real discount rate of the CRF, because every cost is in constant 2024 EUR with no escalation (no nominal rate is mixed with real costs).

    6.49%
    Input default
  • Price of the charging electricity, only in the LCOS including charging. The headline LCOS excludes it (Keiner convention), so that project mode prices the inlet once.

    78.51EUR/MWh
    Input default
  • AC round-trip efficiency chosen by the reference case; not a free input.

    90%
    Reference case
  • Real WACC derived from the PNNL parameters; the model recomputes it from the five PNNL constants instead of storing it.

    Market range No independent European range cited.

    6.49%
    Derived
  • Documents the lower end of the literature range for the power interface; the central case uses Keiner's own 135 EUR/kW.

    150EUR/kW
    Keiner et al. 2026, §3.2
  • Upper working temperature of sodium-ion cells; no hot-climate input is modelled.

    Market range 80 °C (SIB) against 60 °C (Li-ion).

    80°C
    IRENA 2025, Table 2
  • Cross-check of the cell share only, qualitative: the model's cell cost (75 % of 116.3 = 87.2 EUR2024/kWh) is in EUR 2024 and no conversion is cited, so no position is concluded.

    Market range USD 80-105/kWh cells, 2022.

    80USD/kWh
    IRENA 2025
  • Upper end of the IRENA cell cost; qualitative cross-check only.

    Market range USD 80-105/kWh cells, 2022.

    105USD/kWh
    IRENA 2025
  • Pack cost lower end; qualitative cross-check only (different currency, year and boundary from the system capex).

    Market range USD 90-125/kWh packs, 2022.

    90USD/kWh
    IRENA 2025
  • Pack cost upper end; qualitative cross-check only.

    Market range USD 90-125/kWh packs, 2022.

    125USD/kWh
    IRENA 2025
  • Market cross-check only, in CNY: the scope is not stated, so it is not the default and no conversion is made.

    Market range Single tender.

    1.035CNY/Wh
    SMM 2026
  • Market cross-check only: same order as the model's 133-316 EUR2024/kWh, but in USD 2025 with an unknown scope, so no position is concluded.

    Market range Single tender.

    150USD/kWh
    ESS News 2025
  • LCOS = (CAPEX x CRF + fixed O&M) / mean yearly energy delivered (Keiner convention, charging excluded); the version with charging adds the charging price divided by the round-trip efficiency (PNNL ECC term). CRF over the service life = min(calendar life, cycle life / cycles a year) (PNNL Eq. 5).

    Market range Not applicable.

    —
    Method
  • All costs in constant 2024 EUR, no escalation, discounted at a real rate. The yearly O&M exported to project mode is undiscounted and does not depend on the discount rate.

    Market range Not applicable.

    —
    Scope
  • No cell replacement and no augmentation: the service life ends when the usable energy reaches 80 % or at calendar life, whichever comes first. Project mode replaces the whole asset at that life.

    Market range Not applicable.

    —
    Scope
  • Capacity fade is linear per cycle only. Calendar ageing is not modelled separately: it only caps the life. When the life is calendar-limited, the end-of-life capacity is therefore above 80 %, which is optimistic.

    Market range No independent range cited.

    —
    Limitation
  • Costs are linear in size, so the LCOS does not depend on size. Below about 10 MWh the per-kWh cost is probably underestimated: the calculator raises the extrapolation flag instead of inventing a scaling law.

    Market range No sourced scaling law.

    —
    Limitation
  • The CAPEX is read as an installed system cost (cells, periphery, power interface). It is exported as 'installed': project mode adds only its working-capital layer and contingency (about x1.17 with the defaults), not engineering or site layers.

    Market range Not applicable.

    —
    Scope
  • Over the corners of the slider box the LCOS excluding charging stays within about 49-159 EUR/MWh, the CAPEX within 130-316 EUR/kWh, the end-of-life capacity within 80-83 % and the energy delivered within about 610-166,000 MWh a year. The slider box is deliberately narrow on cycles and discount rate so that every corner stays inside the sourced envelope; outside it the conservative 2-hour case would exceed it.

    Market range Not applicable.

    —
    Bounds