PV module yield & levelized cost (module-level)
Turns a PV module datasheet into annual yield, degradation-adjusted lifetime energy and levelized cost.
Inputs
Nameplate DC power of a single module at standard test conditions, as printed on the datasheet.
min 100 · max 800 · step 5 · W
Front-side conversion efficiency at standard test conditions. Sets the module area for a given power.
min 5 · max 30 · step 0.1 · %
Power lost per degree of cell temperature above 25 C. Negative by physics.
min -0.6 · max -0.15 · step 0.01 · %/°C
Yearly loss of rated power over the module lifetime, as warranted on the datasheet.
min 0.1 · max 2 · step 0.05 · %/year
Extra annual energy collected on the rear face. Zero for a monofacial module.
min 0 · max 25 · step 1 · %
Solar energy received per square metre of module plane over one year, at the site.
min 600 · max 2600 · step 25 · kWh/m2/year
Site air temperature during productive hours. Drives the thermal derating.
min -10 · max 45 · step 1 · °C
Purchase price of the module per watt-peak, excluding everything else.
min 0.03 · max 0.5 · step 0.005 · EUR/Wp
Size of the installation this module belongs to. Only sets the cost of everything that is not the module.
min 1 · max 500000 · step 1 · kWp
Real weighted average cost of capital used to annualize the investment.
min 0 · max 0.2 · step 0.005 · ratio
Years over which the investment is annualized and the energy is levelized.
min 5 · max 40 · step 1 · years
Results
Levelized cost of electricity (module + balance of system)
Headline cost of one MWh delivered over the lifetime
Levelized cost — module share only
What the module itself contributes to the MWh
Specific yield
Annual energy per kilowatt-peak installed
Annual energy, first year
Before any degradation
Average annual energy over lifetime
Degradation already accounted for
Lifetime energy
Total delivered over the economic lifetime
Peak sun hours
Equivalent full-load hours at 1000 W/m2
Performance ratio
Share of the theoretical yield actually delivered
Loss factor (excluding rear-side gain)
Thermal, soiling, DC, inverter and residual losses combined
Operating cell temperature
Where the thermal derating comes from
Thermal derating factor
Power kept once the cell is hot
End-of-life power ratio
Rated power still available in the final year
Module area
Surface needed for the rated power
Module capacity
Nameplate power in kilowatt-peak
Solar energy consumed per kWh delivered
Reciprocal of the real-world efficiency
Real-world efficiency
Field efficiency, losses included
Installed cost, per module
Module plus its share of everything else
Module purchase cost
The module alone
Balance-of-system cost, per module
Structure, inverter, cabling, civil works, grid connection
Scaled balance-of-system cost
Falls as the plant grows
Installed cost per kilowatt-peak
The number a developer compares
Installed cost per square metre
For area-constrained sites
Annualized CAPEX
Investment spread over the lifetime
Annual O&M cost
Operation and maintenance
Total annual cost
Capital charge plus O&M
About
Calculator context
About
Calculator context
Reads a photovoltaic module the way its datasheet describes it — nameplate power in watts, efficiency, temperature coefficient, annual degradation, rear-side gain — and returns what a developer needs: module area, peak sun hours, performance ratio, first-year and lifetime-average energy, and the levelized cost of the electricity it delivers. The thermal derating follows the NOCT cell-temperature model; the cost side splits the module price from the balance-of-system cost, which is scaled with plant size across the observed European CAPEX range. Module-level on purpose: it is the object a vendor sells and a procurement team compares, not a plant.
Model
72 variables — inputs, calculations and outputs, with their dependencies.
Model
72 variables — inputs, calculations and outputs, with their dependencies.
| Variable | Value | Unit | Depends on |
|---|---|---|---|
| 610 | W | — | |
| 21.8 | % | — | |
| -0.29 | %/°C | — | |
| 0.55 | %/year | — | |
| 0 | % | — | |
| 1300 | kWh/m2/year | — | |
| 15 | °C | — | |
| 0.107 | EUR/Wp | — | |
| 1000 | kWp | — | |
| 0.07 | ratio | — | |
| 30 | years | — |
| Variable | Formula | Unit | Depends on |
|---|---|---|---|
if((<=)+(<=)+(>)+(<=)+(<=)+(<)+(<)+(<=)+(>)+(<)+(<)>,,) | bool | ||
* | W/m2 | ||
- | °C | ||
- | ratio | ||
- | ratio | ||
- | ratio | ||
- | ratio | ||
+ * | ratio | ||
if( * < , , ( - ) / max( * * , )) | ratio | ||
* | kWh/year | ||
* | kWh/year | ||
if( < , / max(, ), ( * ( + )^) / max(( + )^ - , )) | ratio | ||
* | EUR/year |
| Variable | Formula | Unit | Depends on |
|---|---|---|---|
* | kWp | ||
/ max( * * , ) | m2 | ||
/ max( * , ) | h/year | ||
+ ( - ) / max(, ) * | °C | ||
+ * * | ratio | ||
* * * * | ratio | ||
* | ratio | ||
* | kWh/kWp/year | ||
* | kWh/year | ||
( - * )^ | ratio | ||
* | MWh/year | ||
* | MWh | ||
/ max(, ) | kWh/kWh | ||
/ max(, ) | ratio | ||
* | EUR | ||
clamp( * ( / max(, ))^, , ) | EUR/kWp | ||
* | EUR | ||
+ | EUR | ||
/ max(, ) | EUR/kWp | ||
/ max(, ) | EUR/m2 | ||
* | EUR/year | ||
* | EUR/year | ||
+ | EUR/year | ||
/ max(, ) | EUR/MWh | ||
/ max(, ) | EUR/MWh |
Assumptions
23 assumptions used in the calculations
Assumptions
23 assumptions used in the calculations
Évite les divisions par zéro et la propagation de NaN.
Market range Sans objet (paramètre numérique).
0.000001Constante de stabilité numérique.Neutre multiplicatif, utilisé dans les facteurs de dérating.
Market range Sans objet.
1Constante numérique.Borne de comparaison des gardes d'entrée.
Market range Sans objet.
0Constante numérique.Borne haute d'un pourcentage physique.
Market range Sans objet.
100%Convention d'unité.Convertit un pourcentage 0–100 en fraction 0–1.
Market range Sans objet.
0.01Conversion d'unité.Convertit des watts en kilowatts.
Market range Sans objet.
0.001Conversion d'unité.Convertit des kWh en MWh.
Market range Sans objet.
0.001Conversion d'unité.Éclairement des conditions standard de test : c'est lui qui définit le watt-crête.
Market range 1000 W/m2, valeur normative unique.
1000W/m2IEC 61215 / IEC 60904-3, conditions STC.Température de cellule de référence des conditions standard, origine du dérating thermique.
Market range 25 °C, valeur normative unique.
25°CIEC 61215 / IEC 60904-3, conditions STC.Température nominale de cellule en fonctionnement : le module chauffe au-dessus de l'ambiante.
Market range 43 à 46 °C sur les modules c-Si commerciaux.
45°CValeur imprimée sur les fiches produit (Jinko 78HL4-BDV : 45 ± 2 °C).Ambiante des conditions NOCT, terme soustrait du modèle de température de cellule.
Market range 20 °C, valeur normative unique.
20°CConditions NOCT : 800 W/m2, 20 °C, vent 1 m/s.Éclairement des conditions NOCT, dénominateur du modèle de température de cellule.
Market range 800 W/m2, valeur normative unique.
800W/m2Conditions NOCT : 800 W/m2, 20 °C, vent 1 m/s.Éclairement moyen pondéré par l'énergie, rapporté aux STC : le module ne travaille pas à 1000 W/m2 mais autour de 650.
Market range 0,55 à 0,75 selon la latitude et le climat.
0.65Moyenne pondérée par l'énergie sur une année de latitude moyenne.Pertes par salissure : poussière et dépôts entre deux nettoyages.
Market range 1 % (climat humide) à 5 % (climat aride ou poussiéreux).
0.02Défaut de pertes de PVWatts, poste salissure.Pertes côté continu : désappariement des modules, câblage, diodes.
Market range 2 % à 4 %.
0.03Défaut de pertes de PVWatts, postes mismatch et wiring.Pertes de conversion continu-alternatif au point de fonctionnement nominal.
Market range 1,5 % à 3 %.
0.02Rendement d'onduleur de 97 à 98,5 % sur les onduleurs string et centraux actuels.Pertes résiduelles : dégradation initiale sous lumière, ombrages, disponibilité, écrêtage.
Market range 3 % à 8 % selon le site et la conception.
0.05Complément aux postes explicites pour retomber sur les 14 % de pertes système par défaut de PVWatts.Coût du reste du système (structure, onduleur, câblage, génie civil, raccordement, installation) hors modules, pour une centrale de référence de 1 MWp.
Market range 350 à 1700 EUR/kWp selon le segment.
700EUR/kWpCAPEX solaire européen 2026 : de 460 EUR/kWp (grande échelle) à 1620 EUR/kWp (résidentiel), modules inclus ; la part hors modules domine.Plancher du coût hors modules, atteint sur les très grandes centrales au sol.
Market range Plancher observé du segment utility.
350EUR/kWpBorne basse du CAPEX européen grande échelle (460 EUR/kWp tout compris, modules déduits).Plafond du coût hors modules, atteint sur les petites installations résidentielles.
Market range Plafond observé du segment résidentiel.
1700EUR/kWpBorne haute du CAPEX européen résidentiel (1620 EUR/kWp tout compris).Taille de centrale de référence à laquelle le coût hors modules vaut sa valeur de référence.
Market range Sans objet (point de référence).
1000kWpPoint d'ancrage de la courbe d'échelle, choisi à 1 MWp.Exposant de la loi d'échelle du coût hors modules : un parc dix fois plus grand ne coûte pas dix fois plus par kWp.
Market range -0,10 à -0,20 selon les segments comparés.
-0.15Déduit du rapport résidentiel/utility du CAPEX européen 2026 (460 contre 1620 EUR/kWp sur environ trois ordres de grandeur de taille).Exploitation et maintenance annuelles, en fraction du CAPEX installé.
Market range 0,8 % à 1,5 % du CAPEX par an.
0.012Fourchette usuelle du solaire au sol, 1 à 1,5 % du CAPEX par an.
Sources
5 external sources
Sources
5 external sources
- Fraunhofer ISE — Photovoltaics Report (lifetime, degradation, performance ratio)
- Sandia PVPMC — NOCT cell temperature model
- Solar Data Atlas — European solar CAPEX by segment, 2026
- PV Tech / sun.store — European module spot prices, November 2025
- JinkoSolar Tiger Neo 78HL4-BDV — datasheet (NOCT, temperature coefficients)