Skip to main content
Equipment catalogUniversal steam boiler UL-S
Bosch Industrial

Universal steam boiler UL-S

Universal steam boiler UL-S, UL-SX

OtherFired industrial steam boiler
Universal steam boiler UL-S by Bosch Industrial
Steam output
1.25–28t/h
Max steam pressure
30bar
Max steam temperature
235°C

Characteristics

3 of 5 fields · all sourced · retrieved 2026-10-26
Steam output
1.25–28t/h
Max steam pressure
30bar
Max steam temperature
235°C

The UL-S is a three-pass shell steam boiler for 1,250 to 28,000 kg/h of steam at up to 30 bar, configured individually for each application. An integrated economiser saves up to 7% on fuel, an optional condensing heat exchanger can lower the flue gas temperature to as low as 50 °C, and the large furnace allows NOx emissions below 50 mg. Flame and smoke tubes are arranged asymmetrically to drive natural water circulation, while the high steam chamber and three-component control keep pressure and steam quality steady when demand fluctuates. The boiler can be retrofitted for biogas, bio-oil or hydrogen, and is also offered as a heat recovery boiler, as a hybrid with an electrical heater rod, or as the UL-SX with a superheater module for superheated steam.

Manufacturer datasheet (20)

Heat transfer medium
High-pressure saturated steam
Design
Three-pass single-flame tube/smoke tube technology
Energy source
Gas, oil, bio gas, bio oil, hydrogen
Fuel saving with integrated economiser
up to 7%%
Flue gas temperature with optional condensing heat exchanger
up to 50 °C°C
NOx emissions
below 50 mg NOxmg
Overall length L1, UL-S 1250
3962mm
Width B1, UL-S 1250
1929mm
Height H1, UL-S 1250
2262mm
Overall length L1, UL-S 28000
8518mm
Width B1, UL-S 28000
4142mm
Height H1, UL-S 28000
5212mm
Standard insulation
150 mm thick on the boiler ends; 100 mm thick on the boiler shellmm
Dimension and weight tolerances
measurements ± 1%; transportation weight ± 4%; maximum weight ±2%%
Clear passage over operating platform
at least 2 mm
Four-pass variant: output from waste heat
up to 15 % of the nominal output%
Four-pass variant: max. flue gas temperature of the waste heat source
630°C
Four-pass variant: min. flue gas volumes of the waste heat source
500kg/h
Four-pass variant: max. flue gas volumes of the waste heat source
28,000kg/h
Four-pass variant: output range of combinable CHP units
Approx. 0.2 to 4MWel